Displays only in Nitrox mode:
•
Oxygen%: 21 - 50.
•
Oxygen partial pressure display: 1.2 - 1.6 bar depending on the limit
setting.
•
Oxygen Limit Fraction: 1 - 110% with 10% resolution (bar graph).
Logbook/Dive Profi le Memory:
•
Recording interval: 20 seconds (the recording interval can be set to 10s,
30s or 60s with the optional PC-interface unit and software), records the
maximum depth of each interval.
•
Memory capacity: approximately 36 hours of diving with 20 seconds
recording interval.
•
Depth accuracy: 0.3 m [1 ft].
Operating Conditions
•
Normal altitude range: 0 to 3000 m [10000 ft] above sea level.
•
Operating temperature: 0°C to 40°C [32°F to 104°F].
•
Storage temperature: -20°C to +50°C [-4°F to +122°F].
It is recommended that the instrument be stored in a dry place at room
temperature.
NOTE! Do not leave the dive computer in direct sunlight!
Tissue Calculation Model
•
Suunto RGBM algorithm (developed by SUUNTO and Bruce R.
Wienke, BS, MS and PhD).
•
9 tissue compartments.
•
Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480
minutes (on gassing). The off gassing halftimes are slowed down.
•
Reduced gradient (variable) “M” values based on diving habit and dive
violations. The “M” values are tracked up to 100 hours after a dive.
•
The EAN and oxygen exposure calculations are based on
recommendations by R.W. Hamilton, PhD and currently accepted
exposure time limit tables and principles.