Data logging – ACU-RITE DRO 200G User Manual
Page 30
![background image](/manuals/248946/30/background.png)
DRO 200G
Troubleshooting
23
•
If the problem remains in the same display, the readout is in error.
•
If the problem follows the connection change, the linear encoder may be in
error. Refer to the Checking the Linear Encoders section of your encoder
reference manual.
Display overflow errors are indicated by dashes in all digits in an axis display.
A numeric overflow occurs when the intended measurement is too large for the
eight-digit display. Clear the error by returning the machine table into an area
where measurements can again be displayed, selecting a lower display resolution,
setting a new preset, or zeroing the display.
This error may also occur when using the automatic compensation routine while
setting the LEC parameter. An error indicates that the calculated compensation
factor was outside the acceptable range of -9999 to +9999, and usually is the
result of incorrectly entering data. Clear the error and return to the beginning of
the linear error compensation routine. Refer to page 14.
Data Logging
The readout collects information about itself while it is being used. This
information is stored in memory for review at a later time.
Press and hold the
.
key until the software version is displayed. Then press the
SETUP
and
MM
keys simultaneously. Use the
X
key to cycle through the following
information.
Power on time—displayed in decimal hours.
Scale travel distance—the travel distance for each axis is scrolled one after the
other.
Last 3 errors—the most recent three errors are remembered and messages for
the errors are scrolled one after the other.