Readout Operations
DRO 200G
8
Setting Absolute Zero Using an Electronic Edge Finder
1.
Install the electronic edge finder and connect it to the readout.
2.
Make sure that the absolute position is displayed.
3.
Press the
ZERO
key for the appropriate axis.
4.
Move slowly until the electronic edge
finder touches the edge of the workpiece.
The absolute position display will
automatically be set to zero at the center
of the edge finder.
Incremental Zero
From the incremental display, press the
ZERO
key. This sets the display to zero at
the current tool position.
ABS
INCR
ZERO
You don’t have to worry about
overtraveling because the edge
finder probe shaft is flexible. The
readout will zero on contact.