Turbo Air Blower Problems

If Air Blower does not
turn on, go to GFCI trouble shooting section. If Blower turns on go to next step.

2. If Blower turns on for a second, then trips GFCI, go to GFCI troubles shooting section.
Blower may be wet.

3. If Blower turns on, but does not blow air all the way around the bubble ring in spa, or
shuts off by itself after a minute or two, check union o ring tape has been removed during
initial installation. Two pieces of criss-crossed tape are placed over the lower union
connection from the factory. This is used to keep the union o-ring in place and from
falling out during shipping. If BOTH pieces are not removed, the air check valve will not
be allowed to fully open. Result will be little or no air flow into the bubble ring in spa,
and blower overheating. Remove tape and allow blower to cool for 1 hour & retry.
Be careful to keep union o-ring in its groove or spa will leak at that connection.

4. If it is verified blower motor is dry in GFCI troubleshooting and GFCI trips when
Turbo/ Air Blower button is pushed,
Blower motor may need to be replaced. Send Power Pack to service center for repair.

1. Does Turbo / Air Blower turn on? If
NO, check unit plugged in

Is the Temperature display illuminated?

Always check to make sure there is power to the unit.
Unit should always be plugged into a grounded outlet
and NEVER use an extension cord. Check to see if the
display is illuminated.
If unsure if there is power to the outlet, plug a lamp or
blow dryer into outlet to ensure it is working. If you
are still unsure, have an electrician check for you.