Activeforever Spa2Go Portable Spa (Blue) User Manual

Page 10

background image

4a.


5. If Blower runs and above steps have been checked, with spa drained, disconnect
Blower Union nut from Power pack and pull pack away from spa a few inches. Turn
blower on and see if air flows from check valve fitting (Large lower connection on Power
Pack. A 1/4" round peg should pop out of center of check valve and you should feel air
flow when you put you hand in front of fitting. If not, check valve could be stuck in
closed position, or check valve spring rusted shut. Replace check valve or send Power
Pack into service center for repair.

This is the Check Valve, check here to make sure
the 2 pieces of tape have been removed and the
“O” ring is securely in place