Exchange_t1_frame – ACS AET63 BioTRUSTKey User Manual
Page 21

P1
APDU parameter byte 1
P2
APDU parameter byte 2
Lc
APDU command data length
BYTE x
APDU command data
Le
Expected APDU response data length (Le = 0 means no data is expected from the
card)
NOTE
With the T=0 communication protocol it is not possible to transmit data to the card
and from the card in a single command-response pair. Hence, only either Lc or Le
can be greater than 0 in an EXCHANGE_APDU command when a T=0 card is in the
reader. If both parameters have a value greater than 0, the AET63 does not execute
the command and returns an error status.
Response data format
BYT
E 1
...
...
BYT
E N
SW1
SW2
BYTE x
Response data from card (if any)
SW1, SW2
Status code returned by the card.
7.4.4.
EXCHANGE_T1_FRAME
To exchange an APDU (Application Protocol Data Unit) command/response pair between the MCU
card inserted in the AET63 and the host computer using T1 protocol.
Command format
Instruction
Code
Data length
Data
LEN
T1 BLOCK FRAME
A1
H
LEN
Length of APDU command data, N
DATA
T1 Block frame to be sent to the card
Response data format
BYTE 1
...
...
BYTE
N
BYTE x
Response T1 Block from card (if any)
Document Title Here
Document Title Here
Document Title Here
AET63 Reference Manual
Version 2.2
Page 21 of 26