C. orientation – ACR&Artex ME406 HM User Manual
Page 75
25-62-30
Page 75 of 84
Jun 25/13
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406 (453-6603), ME406HM (453-6604)
SUBTASK 25-62-30-410-001
C. Orientation
(1)
Mount the ME406HM ELT parallel to the waterline of the fuselage, along the longitudinal axis,
with the direction-of-flight arrow on the ELT pointing forward.
NOTE: This is the orientation of the primary G-switch in the ELT.
(2)
The ELT may be oriented on any of its horizontal axes in 90° increments.
NOTE: Ensure that the front of the ELT is aligned with the nose of the aircraft with no more
than 5° deflection in any direction to ensure proper operation of the 6-axis G-Switch
sensors.
(3)
All other installation requirements contained herein are applicable and must be adhered to.