Inspection and test procedures, A. checklist, Table 5 elt inspection and test checklist – ACR&Artex ME406 HM User Manual
Page 33
25-62-30
Page 33 of 84
Jun 25/13
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406 (453-6603), ME406HM (453-6604)
TASK 25-62-30-750-802
2. Inspection and Test Procedures
SUBTASK 25-62-30-990-001
A. Checklist
(1)
Table 5 provides a list of the ELT inspection and testing requirements, a copy of which may be
used as a checklist to verify inspection and test completion. The item numbers in the table
correspond to the item identifiers for each task.
NOTE: Items 5a through 5h are mandatory requirements only in Canada, in addition to
meeting the other inspection and test requirements listed in Table 5.
Table 5 ELT Inspection and Test Checklist
ITEM NO.
DESCRIPTION
BY
1
Coax Cable and Wiring Connections Inspection
2
ELT Mounting Tray and Hardware Inspection
3
ELT Battery Pack Inspection
4
G-Switch Functional Check
5a
121.5 MHz Frequency Measurement
5b
Audio Modulation Check
5c
121.5 MHz Power Output Measurement
5d
406 MHz Frequency Measurement
5e
406 MHz Power Output Measurement
5f
Current Draw Test
5g
Digital Message Verification
5h
ELT Reset Check
6
Installed Transmitter Test
7
Antenna Test
8
Inspection and Test Documentation