beautypg.com

Figure 18 metal airframe wiring diagrams – ACR&Artex ME406 HM User Manual

Page 59

background image

25-62-30

Page 59 of 84

Jun 25/13

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406 (453-6603), ME406HM (453-6604)

Figure 18 Metal Airframe Wiring Diagrams

ELT D-SUB

PLUG

CABLE

SHIELD

REMOTE SWITCH

MOLEX PLUG

SHIELD USED AS GROUND WIRE

LIGHT

RESET 1

RESET 2

EXTERNAL ON

G-SWITCH LOOP

G-SWITCH LOOP

GROUND

AUDIO POWER

2

6

13

14

5

12

7

8

8

5

2

7

1

3

6

9

+14V

OR

+28v

UNSWITCHED
POWER

1/2A SLO-BLO FUSE

NOTE: PINS 6 & 9 OF REMOTE

SWITCH ARE INTERNALLY
TIED WITHIN THE REMOTE
SWITCH ASSEMBLY.

NOTE: N/C PINS 1, 3, 4,

9, 10, 11, 15.

RED +

BLK –

AUDIO

INDICATOR

452-6505

METAL AIRFRAME WITH SHIELDED CABLE

ELT D-SUB

PLUG

REMOTE SWITCH

MOLEX PLUG

LIGHT

RESET 1

RESET 2

EXTERNAL ON

G-SWITCH LOOP

G-SWITCH LOOP

GROUND

AUDIO POWER

2

6

13

14

5

12

7

8

8

5

2

7

1

3

6

9

+14V

OR

+28v

UNSWITCHED
POWER

1/2A SLO-BLO FUSE

NOTE: PINS 6 & 9 OF REMOTE

SWITCH ARE INTERNALLY
TIED WITHIN THE REMOTE
SWITCH ASSEMBLY.

NOTE: N/C PINS 1, 3, 4,

9, 10, 11, 15.

RED +

BLK –

AUDIO

INDICATOR

452-6505

METAL AIRFRAME WITH UNSHIELDED CABLE

AIRFRAME

GROUND (TYP.)

AIRFRAME

GROUND (TYP.)

PIN INSERTION END OF MOLEX
PLUG FOR REMOTE SWITCH
ASSEMBLY. HOLE NUMBERING
IS IDENTICAL TO THAT INSCRIBED
ON ACTUAL PLUG. ORIENTATION
SHOWN IS SAME AS INSERTION
ORIENTATION FOR INSTALLED
SWITCH.

9

8

7

6

5

4

3

2

1

SOLDER CUP (BACK) SIDE OF D-SUB PLUG
FOR ELT. HOLE NUMBERING IS IDENTICAL
TO THAT INSCRIBED ON ACTUAL PLUG.

1

9

8

15