beautypg.com

B. harness elt d-sub plug sealing – ACR&Artex ME406 HM User Manual

Page 69

background image

25-62-30

Page 69 of 84

Jun 25/13

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406 (453-6603), ME406HM (453-6604)

(6)

Connect the remote switch harness plug to the ELT, as follows:

(a)

Press two sealant strips (850-0814) against the male pins of the ELT receptacle with the

tacky side against the pins, while peeling the foam backing off each sealant strip.

NOTE: Verify sealant strips match the receptacle shape.

NOTE: Verify the sealant strips are in place on existing installations.

(b)

Plug the remote switch harness plug into the ELT receptacle.

(c)

Screw the thumbscrews into the ELT receptacle retaining nuts until the plug is seated

properly.

(7)

Connect the antenna coax cable to the ELT.

(8)

Tie up excess slack in the harness and coax cable, such that they form drip loops.

NOTE: Steps (1) through (7) are applicable any time the ELT has been removed and

undergoes reinstallation. Step (8) is only applicable at initial installation or if the

wiring or coax cable has been disturbed.

(9)

Test the ELT installation in accordance with the requirements of SUBTASK 25-62-30-750-011

on page 40.

NOTE: It is very important the cockpit remote switch LED immediately begins flashing

continuously upon ELT activation. If the LED fails to start flashing, recheck the

interface wiring and connections between the ELT and the cockpit remote switch.

NOTE: If verification of the digital message (i.e., 406 MHz burst) is desired, follow the

procedures outlined in SUBTASK 25-62-30-750-009 on page 39.

SUBTASK 25-62-30-450-001

B. Harness ELT D-Sub Plug Sealing

(1)

Seal the D-Sub plug at the ELT end to prevent moisture from penetrating the connection, thus

preventing water from beading up and causing bridging between connector pins resulting in

possible activation of the ELT. Use the following procedure:

NOTE: Perform the sealing process once all tests have been satisfactorily completed and all

harness connections have been verified to be correct.

(a)

Disconnect the remote switch harness D-Sub plug from the ELT.

(b)

Separate the D-Sub housing halves.

(c)

Inject Dow Corning® 4 Electrical Insulating Compound or an equivalent meeting MIL-S-

8660C into the back side of the plug, such that the insulating compound surrounds the

D-Sub pin area and covers the back of the plug.

(d)

Reinstall the housing halves.

(e)

Inject Dow Corning® 4 Electrical Insulating Compound or an equivalent meeting MIL-S-

8660C around the male pins of the ELT receptacle.

(f)

Connect the remote switch harness plug to the ELT.