MCS5, MCS15

Programming

17

I

NOTE
Should any programming problems or confusion occur, reset the
Memorized Default Settings by entering the program mode and
setting P-17 to “rSt”.
If recent programming changes were made but not saved, the reset
will return to the last saved defaults, which could differ from the
factory defaults.

P-10

Display Brightness
Control

9

4 = Low
13 = Maximum

P-11

Display ºF or ºC

F

F = Fahrenheit displayed
C = Celsius displayed

P-12

Cycle Pump With
Compressor or
Continuous Pump

OFF

OFF = Cycle with compressor
On = Continuous pump

P-13

Reverse Fan Speeds
During Heating Mode

rEF

nor = Normal fan operation
rEF = Reversed fan in heating

P-14

Continuous Fan or
Cycle Fan with
Compressor

con

CYC = Cycle fan with compressor
con = Continuous fan operation

P-15

Reverse Cycle Heating
or Electric Heat Only
Option Installed (cool-
ing only units)

nor

nor = Reverse cycle heating
ELE = Electric heater installed

P-16

Fan Motor type selec-
tion Shaded Pole or
Split Capacitor.

SC

SP = Shaded pole fan motor
SC = Split capacitor fan motor

P-17

Reset Memorized
Programming Defaults

nor

rSt = Reset defaults
nor = Normal

P-18

Reserved for Future
Option

P-19

Reserved for Future
Option

P-20

Filter Threshold
(x10 hours)

00

00 – 250

P-21

Current Filter Time
(x10 hours)

x10 Hours Using

Current Filter

P-22

Voltage Calibration
(Volts)

AC Voltage

Program

number

Description

Default Range