7 programmable parameters – Dometic MCS15 User Manual
Page 16

EN
Programming
MCS5, MCS15
16
8.6
Restore Memorized Default Settings
The memorized default settings can be restored as follows.
➤ Enter the Program Mode.
➤ Set P-17 to “rSt”.
➤ Exit the Program Mode.
✓ The software version number (e.g. “A12”) appears in the display.
✓ The memorized default settings are restored and the Marine Climate Sys-
tem returns to the Off Mode.
8.7
Programmable Parameters
Programmable Parameters Table
Program
number
Description
Default Range
P-1
Operating Mode
0
0 = Automatic mode
1 = Cool only mode
2 = Heat only mode
P-2
High Fan Speed Limit
(arbitrary units)
95
65 – 95
P-3
Low Fan Speed Limit
(arbitrary units)
55
30 – 64
P-4
Compressor Staging
Time Delay
15
5 – 135 s
P-5
Temperature Sensor
Calibration
Ambient
Temperature
Ambient 10 °F
P-6
Failsafe
3
0 = Minimum protection
1 = Continuous, no display
2 = Continuous, with display
3 = Four failures, reset required
P-7
Low AC Voltage Shut-
down (Volts)
115 V – OFF
220/230 V – OFF
75 – 105
175 – 205
P-8
De-Icing Cycle
1
OFF
1 = On with 5 °F faceplate sensor
differential
2 = On with 7 °F faceplate sensor
differential
P-9
High Water Tempera-
ture Limit (°F)
OFF
100 – 150