York E*BD-(T User Manual
Page 22

246819-BTG-H-0208
22
Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
*
= Single-phase outdoor units only.
*
= Single-phase outdoor units only.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
EABD-F042S, EABD-(T,W)042S**
INDOOR COIL MODEL NO.
FC/MC/PC/UC48
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
1200
1400
1600
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
38.3
43.6
41.6
46.5
49.4
40.5
44.8
42.8
47.6
50.2
42.7
46.1
44.0
48.7
50.9
S.C.
38.3
36.8
30.3
31.3
24.1
40.5
39.8
32.7
33.6
25.5
42.7
42.9
35.1
35.8
27.0
K.W.
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.5
2.4
2.4
2.4
2.4
2.5
75
T.C.
37.0
41.4
39.7
44.3
47.0
39.0
42.8
40.8
45.3
47.4
41.0
44.3
41.9
46.3
47.9
S.C.
37.0
35.8
29.5
30.3
23.7
39.0
38.7
31.9
32.6
25.2
41.0
41.5
34.3
34.9
26.7
K.W.
2.6
2.6
2.6
2.6
2.7
2.6
2.6
2.6
2.7
2.7
2.6
2.6
2.6
2.7
2.7
85
T.C.
35.6
39.3
37.9
42.1
44.6
37.4
40.9
38.8
43.1
44.7
39.3
42.4
39.7
44.0
44.8
S.C.
35.6
34.8
28.8
29.3
23.4
37.4
37.5
31.1
31.6
24.9
39.3
40.1
33.4
34.0
26.5
K.W.
2.8
2.8
2.8
2.9
2.9
2.8
2.9
2.8
2.9
2.9
2.9
2.9
2.8
2.9
3.0
95
T.C.
34.2
37.2
36.0
40.0
42.2
35.9
38.9
36.8
41.0
42.0
37.6
40.5
37.6
41.6
41.8
S.C.
34.2
33.8
28.0
28.3
23.0
35.9
36.3
30.3
30.8
24.6
37.6
38.8
32.6
33.0
26.3
K.W.
3.0
3.1
3.0
3.1
3.2
3.1
3.1
3.0
3.1
3.2
3.1
3.1
3.1
3.2
3.2
105
T.C.
32.4
35.2
33.6
37.3
39.4
34.2
36.8
34.3
38.0
39.4
36.1
38.4
35.1
38.7
39.4
S.C.
32.4
32.2
26.7
27.1
21.7
34.2
34.3
28.9
29.4
23.3
35.8
36.4
31.2
31.6
24.9
K.W.
3.3
3.3
3.2
3.3
3.4
3.3
3.3
3.3
3.4
3.5
3.4
3.4
3.3
3.4
3.5
115
T.C.
30.6
33.2
31.2
34.7
36.7
32.6
34.7
32.0
35.4
36.9
34.6
36.3
32.7
36.0
37.1
S.C.
30.6
30.6
25.5
26.0
20.5
32.3
32.3
27.6
28.1
22.0
33.7
34.0
29.8
30.2
23.6
K.W.
3.5
3.5
3.5
3.6
3.7
3.5
3.6
3.5
3.6
3.7
3.6
3.6
3.5
3.6
3.7
125
T.C.
28.8
31.2
28.8
32.1
33.9
31.0
32.7
29.6
32.7
34.3
33.1
34.2
30.3
33.3
34.7
S.C.
28.8
29.1
24.3
24.8
19.2
30.3
30.4
26.3
26.8
20.7
31.7
31.7
28.4
28.9
22.2
K.W.
3.7
3.7
3.7
3.8
4.0
3.8
3.8
3.7
3.8
4.0
3.8
3.8
3.7
3.9
4.0
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
**
For three-phase, decrease T.C. by 1.0 and S.C. by 0.7.
Air Handler
Coil
T.C.
S.C.
KW
MA14D
FC/MC48D
1.00
1.00
1.00
MA16C
FC/MC48C
1.00
1.00
1.00
AHP/SHP48
–
1.00
1.00
1.00
MV16C*
FC/MC48C
1.00
0.98
1.00
MV20D*
FC/MC48D
1.01
0.99
0.97
AV/SV48*
–
1.01
0.99
0.97
–
HD48
0.99
0.98
0.99
Variable Speed
Furnace *
Coil
T.C.
S.C.
KW
(F,L)L8VC20
FC/MC/PC48C
1.00
1.00
1.00
FL9(C,V)C16
FC/MC/PC48C
1.00
1.00
1.00
FL9(C,V)C20
FC/MC/PC48C
1.00
1.00
1.00
FL9(C,V)D20
FC/MC/PC48D
1.00
1.00
1.00
(F,L)L8VC20
HD48
0.98
0.98
0.98
FL9(C,V)C16
HD48
0.99
0.99
0.99
FL9(C,V)C20
HD48
0.98
0.98
0.98