York E*BD-(T User Manual
Page 19
246819-BTG-H-0208
Unitary Products Group
19
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
EABD-F024S
INDOOR COIL MODEL NO.
FC/MC/PC/UC24
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
600
800
1000
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
21.1
25.4
23.3
29.6
29.1
23.5
27.6
25.0
29.9
29.8
25.9
29.8
26.7
30.2
30.4
S.C.
21.1
18.5
15.7
17.0
13.6
23.5
23.0
19.1
19.9
14.3
25.9
27.5
22.4
22.7
15.1
K.W.
1.3
1.4
1.4
1.4
1.3
1.4
1.4
1.4
1.4
1.3
1.4
1.4
1.3
1.4
1.3
75
T.C.
20.0
22.7
21.9
25.6
27.5
22.3
25.0
23.7
26.9
28.0
24.5
27.3
25.4
28.3
28.4
S.C.
20.0
18.0
15.1
16.1
13.0
22.3
21.8
18.0
18.7
14.2
24.5
25.5
21.0
21.2
15.4
K.W.
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
85
T.C.
19.0
20.0
20.5
21.6
26.0
21.1
22.3
22.3
24.0
27.0
23.2
24.7
24.2
26.4
28.1
S.C.
19.0
17.6
14.5
15.2
12.4
21.1
20.5
17.0
17.5
14.1
23.2
23.5
19.5
19.7
15.8
K.W.
1.6
1.6
1.6
1.6
1.7
1.6
1.6
1.6
1.6
1.7
1.6
1.6
1.7
1.7
1.7
95
T.C.
17.9
17.2
19.1
17.6
24.4
19.9
20.3
20.8
21.1
25.2
21.8
23.5
22.5
24.5
26.0
S.C.
17.9
17.1
13.9
14.3
11.8
19.9
19.7
16.2
16.8
13.5
21.8
22.2
18.6
19.2
15.1
K.W.
1.7
1.7
1.7
1.8
1.8
1.8
1.7
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
105
T.C.
16.9
16.8
17.6
17.4
22.5
18.7
19.5
19.2
20.1
23.2
20.5
22.2
20.7
22.7
23.8
S.C.
16.9
16.2
13.0
13.7
11.3
18.7
18.5
15.4
16.2
12.9
20.5
20.9
17.8
18.7
14.4
K.W.
1.8
1.8
1.8
1.9
2.0
1.9
1.9
1.9
1.9
2.0
1.9
1.9
1.9
1.9
2.0
115
T.C.
16.0
16.4
16.2
17.3
20.7
17.6
18.7
17.6
19.1
21.2
19.2
21.0
19.1
20.9
21.7
S.C.
16.0
15.3
12.2
13.2
10.8
17.6
17.5
14.6
15.7
12.3
19.2
19.6
17.0
18.3
13.8
K.W.
2.0
2.0
1.9
2.0
2.1
2.0
2.0
2.0
2.1
2.1
2.1
2.1
2.0
2.1
2.2
125
T.C.
15.0
16.0
14.8
17.1
18.9
16.4
17.9
16.1
18.1
19.2
17.9
19.7
17.4
19.2
19.6
S.C.
15.0
14.5
11.5
12.6
10.2
16.4
16.4
13.8
15.2
11.7
17.9
18.3
16.2
17.8
13.1
K.W.
2.1
2.1
2.1
2.2
2.3
2.1
2.1
2.1
2.2
2.3
2.2
2.2
2.2
2.2
2.3
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
MA08B
FC/MC24B
1.00
1.01
1.00
MA08B
FC/MC30B
1.00
1.01
1.00
AHP24
–
0.99
0.98
0.99
F*FP030
–
1.00
0.98
1.00
MV12B
FC/MC24B
1.02
1.00
0.97
MV12B
FC/MC30B
1.02
1.00
0.97
AV24
–
1.02
1.00
0.97
–
FC/MC/PC/UC30
1.00
1.00
1.00
–
HC30
1.01
0.99
1.01
–
HD24
1.00
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
(F,L)L8VA12
FC/MC/PC24A
1.00
1.00
0.96
FL9VA12
FC/MC/PC24A
1.00
1.00
0.96
FL9(C,V)B12
FC/MC/PC24B
1.00
0.99
0.96
(F,L)L8VA12
FC/MC/PC30A
1.00
1.00
0.96
FL9VA12
FC/MC/PC30A
1.00
1.00
0.96
FL9(C,V)B12
FC/MC/PC30B
1.00
1.03
0.96
(F,L)L8VA12
HC30
1.00
1.03
0.96
FL9VA12
HC30
1.00
1.01
0.96
(F,L)L8VA12
HD30
1.00
1.01
0.96
FL9VA12
HD30
1.00
1.01
0.96