York E*BD-(T User Manual
Page 20

246819-BTG-H-0208
20
Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
*
= Single-phase outdoor units only.
*
= Single-phase outdoor units only.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
EABD-F030S, EABD-(T,W)030S**
INDOOR COIL MODEL NO.
FC/MC/PC35
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
800
1000
1200
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
28.5
31.9
31.9
34.8
34.4
30.7
32.7
34.5
34.2
33.7
32.9
33.5
37.2
33.6
33.9
S.C.
28.4
26.0
22.0
21.8
16.6
30.6
27.9
25.7
21.2
16.9
32.9
29.8
29.3
20.7
17.3
K.W.
1.8
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
75
T.C.
27.0
29.7
29.6
32.7
33.8
29.1
30.6
31.6
32.6
33.4
31.2
31.5
33.6
32.4
33.0
S.C.
26.9
25.1
21.2
21.1
16.5
29.0
27.2
24.4
21.6
17.2
31.1
29.4
27.5
22.1
17.9
K.W.
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.1
2.0
2.0
2.0
2.0
2.1
85
T.C.
25.4
27.6
27.2
30.7
33.2
27.4
28.5
28.6
31.0
33.2
29.4
29.5
30.0
31.2
33.1
S.C.
25.4
24.1
20.4
20.4
16.5
27.4
26.6
23.1
22.0
17.5
29.4
29.0
25.8
23.6
18.5
K.W.
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.3
2.2
2.2
2.2
2.2
2.3
95
T.C.
23.9
25.5
24.8
28.6
32.6
25.8
26.5
25.6
29.3
32.9
27.7
27.5
26.5
30.0
33.2
S.C.
23.9
23.2
19.6
19.7
16.4
25.7
25.9
21.8
22.4
17.8
27.6
28.6
24.0
25.0
19.1
K.W.
2.3
2.3
2.3
2.4
2.4
2.3
2.3
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.5
105
T.C.
22.5
23.6
22.9
26.2
29.8
24.1
24.6
23.8
26.8
30.1
25.7
25.5
24.6
27.3
30.3
S.C.
22.4
22.1
18.6
18.9
15.4
24.0
24.2
20.9
21.4
16.8
25.6
26.4
23.2
23.9
18.2
K.W.
2.5
2.5
2.5
2.5
2.6
2.5
2.5
2.5
2.6
2.6
2.6
2.6
2.5
2.6
2.6
115
T.C.
21.0
21.8
21.0
23.9
27.1
22.4
22.7
21.9
24.3
27.3
23.8
23.6
22.9
24.7
27.6
S.C.
21.0
21.0
17.6
18.2
14.5
22.3
22.6
20.1
20.5
15.9
23.7
24.2
22.5
22.8
17.2
K.W.
2.6
2.6
2.6
2.7
2.8
2.7
2.7
2.6
2.7
2.8
2.7
2.7
2.7
2.8
2.8
125
T.C.
19.6
19.9
19.1
21.5
24.3
20.7
20.8
20.1
21.8
24.5
21.8
21.7
21.1
22.1
24.8
S.C.
19.5
19.9
16.7
17.4
13.6
20.6
20.9
19.2
19.5
14.9
21.7
22.0
21.7
21.7
16.3
K.W.
2.8
2.8
2.8
2.9
3.0
2.9
2.9
2.8
2.9
3.0
2.9
2.9
2.8
2.9
3.0
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
**
For three-phase, decrease T.C. by 1.0 and S.C. by 0.7.
Air Handler
Coil
T.C.
S.C.
KW
MA12B
FC/MC35B
1.00
1.00
1.00
MA12B
FC/MC42B
1.00
1.00
1.00
AHP30
–
1.00
0.97
1.00
F*FP040
–
0.99
0.97
0.99
MV12B*
FC/MC35B
1.02
1.00
0.98
MV12B*
FC/MC42B
1.02
1.00
0.98
MV16C*
FC/MC35C
1.02
1.00
0.98
MV16C*
FC/MC42C
1.02
1.00
0.98
AV36*
–
1.02
1.00
0.98
–
FC/MC/PC/UC42
1.00
1.00
1.00
–
HC36
0.99
0.97
0.99
–
HD36
1.01
1.00
1.01
Variable Speed
Furnace *
Coil
T.C.
S.C.
KW
(F,L)L8VB16
FC/MC/PC35B
1.02
1.01
0.98
FL9(C,V)B12
FC/MC/PC35B
1.02
1.01
0.98
(F,L)L8VC16
FC/MC/PC35C
1.02
1.00
0.98
FL9(C,V)C16
FC/MC/PC35C
1.02
1.01
0.98
(F,L)L8VB16
FC/MC/PC42B
1.02
1.01
0.98
FL9(C,V)B12
FC/MC/PC42B
1.02
1.01
0.98
(F,L)L8VC16
FC/MC/PC42C
1.02
1.00
0.98
FL9(C,V)C16
FC/MC/PC42C
1.02
1.01
0.98
(F,L)L8VB16
HC36
1.02
1.01
0.98
FL9(C,V)B12
HC36
1.02
1.01
0.98
(F,L)L8VB16
HD36
1.02
1.01
0.98
FL9(C,V)B12
HD36
1.02
1.01
0.98