beautypg.com

Table 17: electric heat multipliers, 28 unitary products group, Voltage kw cap. multiplier nominal rating 240 – York PREDATOR DR090 User Manual

Page 28

background image

246721-YTG-C-0606

28

Unitary Products Group

NOTE: Electric heaters are rated at nominal voltage. Use

this table to determine the electric heat capacity for
heaters supplied at lower voltages.

TABLE 15: ELECTRICAL DATA DR150 W/O PWRD CONVENIENCE OUTLET

RLA

LRA

FLA

3

5

3

5

3

5

3

5

3

5

ea.

ea.

ea.

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

None

--

--

61.9

67.1

67.4

72.6

80

80

80

90

2TP04521825

13.5

37.5

61.9

67.1

67.4

73.8

80

80

80

90

2TP04522425

18.0

50.0

76.1

82.6

83.0

89.5

80

90

90

90

2TP04523625

25.5

70.8

102.1

108.6

109.0

115.5

110

110

110

125

2TP04525425 40.6

112.7

154.5

161.0

161.4

167.9

175

175

175

175

None

--

--

61.9

67.1

67.4

72.6

80

80

80

90

2TP04521825

18.0

43.3

67.8

74.3

74.6

81.1

80

80

80

90

2TP04522425

24.0

57.7

85.8

92.3

92.7

99.2

90

100

100

100

2TP04523625

34.0

81.8

115.9

122.4

122.7

129.2

125

125

125

150

2TP04525425 54.0

129.9

143.5

150.0

150.4

156.9

175

175

175

175

None

--

--

27.4

30.2

29.6

32.4

35

35

35

40

2TP04521846

18

22.6

33.7

37.2

36.4

39.9

35

40

40

40

2TP04522446

24

30.1

42.7

46.2

45.5

49

45

50

50

50

2TP04523646

34

42.7

57.7

61.2

60.5

64

60

70

70

70

2TP04525446

54

67.8

71.6

75.1

74.3

77.8

80

90

80

90

None

--

--

22.5

24.4

24.3

26.2

25

30

30

30

2TP04521858

18

18.1

26.8

29.2

29

31.4

30

30

30

35

2TP04522458

24

24.1

34

36.4

36.2

38.6

35

40

40

40

2TP04523658

34

34.1

46

48.4

48.3

50.6

50

50

50

60

2TP04525458

54

54.2

57.1

59.5

59.3

61.7

70

70

70

70

*

Voltage

Compressors

OD Fan

Motors

Supply Blower

Motor FLA

Pwr Exh

Motor

Pwr

Conv

Outlet

Electric Heater

Model No.

Actual

KW

Heater

Amps

Min. Circuit

Ampacity

(Amps)

MCA w/Power

Exhaust

(Amps)

Max Fuse* Size

(Amps)

Max Fuse Size

w/Power

Exhaust

(Amps)

FLA

FLA

208

20.0

146.0

1.5

10.9

16.1

5.5

0.0

230

20.0

146.0

1.5

10.9

16.1

5.5

0.0

460

8.4

73.0

0.8

5.3

8.1

2.2

0.0

575

7.1

60.0

0.6

4.1

6.0

1.8

0.0

Maximum HACR breaker of the same AMP size is applicable.

TABLE 16: ELECTRICAL DATA DR150 W/PWRD CONVENIENCE OUTLET

RLA

LRA

FLA

3

5

3

5

3

5

3

5

3

5

ea.

ea.

ea.

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

None

--

--

71.9

77.1

77.4

82.6

90

90

90

100

2TP04521825

13.5

37.5

73.0

79.5

79.8

86.3

90

90

90

100

2TP04522425

18.0

50.0

88.6

95.1

95.5

102.0

90

100

100

110

2TP04523625

25.5

70.8

114.6

121.1

121.5

128.0

125

125

125

150

2TP04525425 40.6

112.7

167.0

173.5

173.9

180.4

175

175

175

200

None

--

--

71.9

77.1

77.4

82.6

90

90

90

100

2TP04521825

18.0

43.3

80.3

86.8

87.1

93.6

90

90

90

100

2TP04522425

24.0

57.7

98.3

104.8

105.2

111.7

100

110

110

125

2TP04523625

34.0

81.8

128.4

134.9

135.2

141.7

150

150

150

150

2TP04525425 54.0

129.9

156.0

162.5

162.9

169.4

175

175

175

175

None

--

--

32.4

35.2

34.6

37.4

40

40

40

45

2TP04521846

18

22.6

39.9

43.4

42.7

46.2

40

45

45

50

2TP04522446

24

30.1

49

52.5

51.7

55.2

50

60

60

60

2TP04523646

34

42.7

64

67.5

66.7

70.2

70

70

70

80

2TP04525446

54

67.8

77.8

81.3

80.6

84.1

90

90

90

90

None

--

--

26.5

28.4

28.3

30.2

30

35

35

35

2TP04521858

18

18.1

31.8

34.2

34

36.4

35

35

35

40

2TP04522458

24

24.1

39

41.4

41.2

43.6

40

45

45

45

2TP04523658

34

34.1

51

53.4

53.3

55.6

60

60

60

60

2TP04525458

54

54.2

62.1

64.5

64.3

66.7

70

70

70

70

*

Voltage

Compressors

OD Fan

Motors

Supply Blower

Motor FLA

Pwr Exh

Motor

Pwr

Conv

Outlet

Electric Heater

Model No.

Actual

KW

Heater

Amps

Min. Circuit

Ampacity

(Amps)

MCA w/Power

Exhaust

(Amps)

Max Fuse* Size

(Amps)

Max Fuse Size

w/Power

Exhaust

(Amps)

FLA

FLA

208

20.0

146.0

1.5

10.9

16.1

5.5

10.0

230

20.0

146.0

1.5

10.9

16.1

5.5

10.0

5.0

460

8.4

73.0

0.8

0.6

5.3

8.1

2.2

Maximum HACR breaker of the same AMP size is applicable.

4.1

6.0

1.8

4.0

575

7.1

60.0

TABLE 17: ELECTRIC HEAT MULTIPLIERS

VOLTAGE

kW Cap. Multiplier

NOMINAL

RATING

240

208

0.75

230

0.92

480

460

0.92

600

575