beautypg.com

26 unitary products group – York PREDATOR DR090 User Manual

Page 26

background image

246721-YTG-C-0606

26

Unitary Products Group

TABLE 11: ELECTRICAL DATA DR090 W/O PWRD CONVENIENCE OUTLET

RLA

LRA

FLA

1.5

2

1.5

2

1.5

2

1.5

2

1.5

2

ea.

ea.

ea.

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

None

--

--

38.7

40.7

44.2

46.2

50

50

50

50

2TP04520925

6.8

18.9

38.7

40.7

44.2

46.2

50

50

50

50

2TP04521825

13.5

37.5

54.6

57.1

61.5

64.0

60

60

70

70

2TP04522425

18.0

50.0

70.2

72.7

77.1

79.6

80

80

80

80

2TP04523625

25.5

70.8

96.2

98.7

103.1

105.6

100

100

110

110

None

--

--

38.7

40.7

44.2

46.2

50

50

50

50

2TP04520925

9.0

21.7

38.7

40.7

44.2

46.2

50

50

50

50

2TP04521825

18.0

43.3

61.9

64.4

68.8

71.3

70

70

70

80

2TP04522425

24.0

57.7

79.9

82.4

86.8

89.3

80

90

90

90

2TP04523625

34.0

81.8

110.0

112.5

116.9

119.4

110

125

125

125

None

--

--

19.8

20.8

22

23

25

25

25

25

2TP04520946

9

11.3

19.8

20.8

22

23

25

25

25

25

2TP04521846

18

22.6

30.9

32.2

33.7

34.9

35

35

35

35

2TP04522446

24

30.1

40

41.2

42.7

44

40

45

45

45

2TP04523646

34

42.7

55

56.2

57.7

59

60

60

60

60

None

--

--

15.1

16.3

16.9

18.1

20

20

20

20

2TP04520958

9

9.0

15.1

16.3

16.9

18.1

20

20

20

20

2TP04521858

18

18.1

24.7

26.2

26.9

28.4

25

30

30

30

2TP04522458

24

24.1

31.9

33.4

34.1

35.6

35

35

35

40

2TP04523658

34

34.1

43.9

45.4

46.1

47.6

45

50

50

50

*

Maximum HACR breaker of the same AMP size is applicable.

2.4

3.6

1.8

0.0

575

5.1

44.0

0.6

3.1

4.1

2.2

0.0

460

6.7

54.0

0.8

0.0

230

13.1

110.0

1.5

6.2

8.2

5.5

0.0

Max Fuse* Size

w/Power

Exhaust (Amps)

FLA

FLA

208

13.1

110.0

1.5

6.2

8.2

5.5

Heater

Amps

Min. Circuit

Ampacity

(Amps)

MCA w/Power

Exhaust (Amps)

Max Fuse* Size

(Amps)

Pwr Exh

Motor

Pwr

Conv

Outlet

Electric Heater

Model No.

Actual

KW

Voltage

Compressors

OD Fan

Motors

Supply Blower

Motor FLA

TABLE 12: ELECTRICAL DATA DR090 WITH PWRD CONVENIENCE OUTLET

RLA

LRA

FLA

1.5

2

1.5

2

1.5

2

1.5

2

1.5

2

ea.

ea.

ea.

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

None

--

--

48.7

50.7

54.2

56.2

60

60

60

60

2TP04520925

6.8

18.9

48.7

50.7

54.2

56.2

60

60

60

60

2TP04521825

13.5

37.5

67.1

69.6

74.0

76.5

70

70

80

80

2TP04522425

18.0

50.0

82.7

85.2

89.6

92.1

90

90

90

100

2TP04523625

25.5

70.8

108.7

111.2

115.6

118.1

110

125

125

125

None

--

--

48.7

50.7

54.2

56.2

60

60

60

60

2TP04520925

9.0

21.7

48.7

50.7

54.2

56.7

60

60

60

60

2TP04521825

18.0

43.3

74.4

76.9

81.3

83.8

80

80

90

90

2TP04522425

24.0

57.7

92.4

94.9

99.3

101.8

100

100

100

110

2TP04523625

34.0

81.8

122.5

125.0

129.4

131.9

125

125

150

150

None

--

--

24.8

25.8

27

28

30

30

30

30

2TP04520946

9

11.3

24.8

25.8

27

28

30

30

30

30

2TP04521846

18

22.6

37.2

38.4

39.9

41.2

40

40

40

45

2TP04522446

24

30.1

46.2

47.5

49

50.2

50

50

50

60

2TP04523646

34

42.7

61.2

62.5

64

65.2

70

70

70

70

None

--

--

19.1

20.3

20.9

22.1

20

25

25

25

2TP04520958

9

9.0

19.1

20.3

21.1

22.6

20

25

25

25

2TP04521858

18

18.1

29.7

31.2

31.9

33.4

30

35

35

35

2TP04522458

24

24.1

36.9

38.4

39.1

40.6

40

40

40

45

2TP04523658

34

34.1

48.9

50.4

51.1

52.6

50

60

60

60

*

Maximum HACR breaker of the same AMP size is applicable.

2.4

3.6

1.8

4.0

575

5.1

44.0

0.6

3.1

4.1

2.2

5.0

460

6.7

54.0

0.8

6.2

8.2

5.5

10.0

230

13.1

110.0

1.5

FLA

FLA

208

13.1

110.0

1.5

6.2

8.2

5.5

10.0

Min. Circuit

Ampacity

(Amps)

MCA w/Power

Exhaust (Amps)

Max Fuse* Size

(Amps)

Max Fuse Size

w/Power

Exhaust (Amps)

Voltage

Compressors

OD Fan

Motors

Supply Blower

Motor FLA

Pwr Exh

Motor

Pwr

Conv

Outlet

Electric Heater

Model No.

Actual

KW

Heater

Amps