Operating limits, Power output, Input voltage – Xantrex Technology 1000 User Manual
Page 38
Operating Limits
975-0127-01-01
4–3
Operating Limits
Power Output
The XPower 1000 can deliver up to 1000 watts continuous.
The wattage rating applies to resistive loads such as incandescent lights.
Input Voltage
The allowable XPower 1000 input voltage ranges are shown in the
following table:
Operating
Condition
Voltage Range
Comment
Normal
10.5 V–15.0 V
Optimum
Performance
12.0 V–13.0 V
Low Voltage Alarm
11.0 V or less
The audible low battery alarm
sounds.
Low Voltage
Shutdown
less than 10.5 V The inverter shuts down to protect the
battery from being over-discharged.
High Voltage
Shutdown
15.0 V or more
The inverter shuts down to protect
itself from excessive input voltage.
Note: Although the XPower 1000
incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.