Operating Limits

975-0127-01-01

4–3

Operating Limits

Power Output

The XPower 1000 can deliver up to 1000 watts continuous.

The wattage rating applies to resistive loads such as incandescent lights.

Input Voltage

The allowable XPower 1000 input voltage ranges are shown in the
following table:

Operating
Condition

Voltage Range

Comment

Normal

10.5 V–15.0 V

Optimum
Performance

12.0 V–13.0 V

Low Voltage Alarm

11.0 V or less

The audible low battery alarm
sounds.

Low Voltage
Shutdown

less than 10.5 V The inverter shuts down to protect the

battery from being over-discharged.

High Voltage
Shutdown

15.0 V or more

The inverter shuts down to protect
itself from excessive input voltage.
Note: Although the XPower 1000
incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.