beautypg.com

Calculating fuse / circuit breaker size, Calculating fuse/circuit breaker size – Xantrex Technology 1000 User Manual

Page 27

background image

Installation

3–8

975-0127-01-01

Calculating Fuse/Circuit Breaker Size

Because your batteries can provide thousands of amps of short-circuit
current, you need fuses or circuit breakers that can safely withstand the
short-circuit current that the batteries can produce.

To select the correct fuse type and size:

1. Determine the total short-circuit current rating for your batteries. For

example:

If you are using one battery to power your inverter and its short-
circuit current rating is 500 A, the total short-circuit current rating
is 500 A.

If you are powering your inverter with two 12 V batteries
connected in parallel, and each battery has a short-circuit current
rating of 500 A, the total short-circuit current rating is 1000 A.

If you are powering your inverter with two 6 V batteries
connected in series, and each battery has a short-circuit current
rating of 500 A, the total short-circuit current rating is 500 A.

2. Once you have determined the total short-circuit current rating of

your batteries, pick the fuse/circuit breaker’s interrupt capacity based
on the short-circuit current calculated in step 1.

3. Pick the fuse/circuit breaker’s current rating based on the product

used: 150 Adc

Fuses can be bought at any marine supply store, RV supply store, or
electrical products store.

Important:

For batteries connected in parallel, the total short-circuit current

rating is the sum of the short-circuit current ratings of all of the batteries
connected in parallel. For batteries connected in series, the total short-circuit
current rating is equal to the short-circuit rating of a single battery.