York SPLIT-SYSTEM YHJD18 THRU 60 User Manual
Page 6

398612-YTG-B-0608
6
Johnson Controls Unitary Products
— = Not applicable.
13 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
YHJD18S21S1
AV24 17 –
565
18.0
13.4
14.00
12.00
YHJD24S21S1
AV24 17 –
770
23.0
17.5
14.00
12.00
YHJD30S21S1
AV36 21 –
1015
29.0
22.0
14.00
12.00
YHJD36S21S1
AV36 21 –
1270
35.0
26.2
14.00
12.00
AV/SV48 24
–
1270
35.0
26.2
14.00
12.00
YHJD42S21S1
AV/SV48 24
–
1415
41.0
29.4
13.85
11.00
AV/SV60 24
–
1410
41.0
29.4
13.85
11.00
F4FV060 24
–
1410
41.0
29.4
13.85
11.00
YHJD48S21S1
AV/SV48 24
–
1610
46.0
33.8
13.25
11.00
AV/SV60 24
–
1655
46.0
33.6
13.25
11.00
F4FV060 24
–
1655
46.0
33.6
13.30
11.00
13 SEER HP WITH AHP / SHP / F*FP
YHJD18S21S1
AHP18 17
–
650
18.0
12.9
13.00
11.00
AHP24 17
–
655
18.0
13.0
13.00
11.00
F4FP024 17
–
655
18.0
13.0
13.00
11.00
YHJD24S21S1
AHP24 17
–
830
23.0
16.9
13.00
11.00
AHP30 17
–
795
23.0
16.8
13.00
11.00
F4FP030 17
–
795
23.0
16.8
13.00
11.00
YHJD30S21S1
AHP30 17
–
1015
29.0
21.2
13.00
11.00
AHP36 21
–
1040
29.0
21.2
13.00
11.00
F4FP040 21
–
1040
29.0
21.2
13.00
11.00
YHJD36S21S1
AHP36 21
–
1235
35.0
25.6
13.00
11.00
AHP42 21
–
1255
35.0
25.6
13.00
11.00
AHP/SHP60 24
–
1270 35.0 26.2 14.00
12.00
F4FP045 24
–
1200
35.0
25.6
13.00
11.00
F5FP048 24
–
1200
35.0
26.2
14.00
12.00
F5FP060 24
–
1200
35.0
26.2
14.00
12.00
YHJD42S21S1
AHP/SHP48 24
–
1400 40.0 29.0 13.00
11.00
AHP/SHP60 24
–
1400 41.0 29.4 13.85
11.00
F4FP045 24
–
1400
40.0
29.0
13.00
11.00
F5FP048 24
–
1400
41.0
29.4
13.85
11.00
F5FP060 24
–
1400
41.0
29.4
13.85
11.00
YHJD48S21S1
AHP/SHP48 24
–
1600 45.0 33.2 13.00
11.00
AHP/SHP60 24
–
1600 46.0 33.6 13.30
11.00
F5FP060 24
–
1600
46.0
33.6
13.30
11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL
W
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.