York SPLIT-SYSTEM YHJD18 THRU 60 User Manual
Page 18

398612-YTG-B-0608
18
Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO.
YHJD30S21S1
INDOOR COIL MODEL NO.
AHP30
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
800
1000
1200
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
25.7 27.6 26.2 29.0 32.9 27.1 30.3 28.1 31.3 32.9 28.5 32.9 30.0 33.5 33.0
S.C.
24.2 24.2 20.1 20.5 20.0 24.2 24.2 21.8 22.4 20.2 24.2 24.2 23.5 24.4 20.3
KW
1.5 1.6 1.5 1.6 1.7 1.6 1.6 1.6 1.6 1.7 1.6 1.7 1.6 1.7 1.7
75
T.C.
25.2 27.4 26.0 29.2 31.2 26.4 29.1 27.3 30.3 31.8 27.6 30.8 28.5 31.5 32.4
S.C.
24.2 24.2 20.3 21.1 18.9 24.2 24.2 21.6 22.1 19.3 24.2 24.2 22.9 23.1 19.6
KW
1.7 1.7 1.7 1.8 1.8 1.7 1.8 1.7 1.8 1.8 1.7 1.8 1.8 1.8 1.8
85
T.C.
24.7 27.3 25.9 29.4 29.6 25.7 28.0 26.5 29.4 30.7 26.7 28.7 27.1 29.4 31.9
S.C.
24.2 24.2 20.6 21.6 17.8 24.2 24.2 21.4 21.7 18.4 24.2 24.2 22.2 21.8 18.9
KW
1.9 1.9 1.9 2.0 2.0 1.9 1.9 1.9 2.0 2.0 1.9 1.9 1.9 2.0 2.0
95
T.C.
24.2 27.1 25.7 29.7 27.9 25.0 26.9 25.7 28.5 29.6 25.8 26.6 25.6 27.4 31.4
S.C.
24.2 24.2 20.8 22.2 16.7 24.2 24.2 21.2 21.3 17.5 24.2 24.2 21.6 20.5 18.2
KW
2.0 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.2
105
T.C.
23.4 25.3 24.5 27.9 26.9 24.2 25.6 24.6 27.2 28.2 25.0 25.9 24.7 26.6 29.4
S.C.
23.4 24.1 20.6 21.5 16.1 24.2 24.1 21.5 21.6 16.7 24.2 24.2 22.4 21.7 17.3
KW
2.2 2.2 2.2 2.3 2.3 2.2 2.3 2.2 2.3 2.3 2.2 2.3 2.3 2.3 2.3
115
T.C.
22.6 23.4 23.2 26.1 26.0 23.4 24.3 23.5 25.9 26.7 24.3 25.2 23.9 25.8 27.4
S.C.
22.6 23.4 20.3 20.7 15.5 23.4 24.1 21.8 21.8 15.9 24.2 24.2 23.3 22.9 16.3
KW
2.3 2.4 2.4 2.5 2.4 2.4 2.4 2.4 2.5 2.5 2.4 2.4 2.4 2.5 2.5
125
T.C.
21.8 21.6 22.0 24.3 25.0 22.6 23.0 22.5 24.7 25.2 23.5 24.4 23.0 25.0 25.4
S.C.
21.8 21.6 20.0 20.0 14.9 22.6 23.0 22.1 22.1 15.1 23.5 24.2 23.0 24.2 15.3
KW
2.5 2.5 2.5 2.6 2.6 2.5 2.6 2.5 2.6 2.6 2.6 2.6 2.6 2.6 2.7
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
–
FC/MC/PC/UC32
1.00 1.00 1.00
–
FC/MC/PC/UC35
1.00 1.00 1.00
–
FC/MC/PC/UC37
1.00 1.00 1.00
–
FC/MC/PC/UC43
1.00 1.00 1.00
–
HC36
1.00 1.00 1.00
–
HC42
1.00 1.00 1.00
–
HD36
1.00 1.00 1.00
–
MH24S
1.00 1.00 1.00
–
MH30S
1.00 1.00 1.00
AHP36
–
1.00 1.00 1.00
AV36
–
1.02 1.03 0.93
F4FP040
–
1.00 1.00 1.00
MV12B
FC/MC35B
1.02 1.02 0.93
MV16C
FC/MC35C
1.02 1.03 0.93
MA12B
FC/MC35B
1.00 1.00 1.00
MV12B
FC/MC43B
1.02 1.02 0.93
MV16C
FC/MC43C
1.02 1.03 0.93
MA12B
FC/MC43B
1.00 1.00 1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
PV8*A12
FC/MC/PC32A
1.01 1.01 0.92
PV9*A12
FC/MC/PC32A
1.01 1.01 0.92
PV8*B16
FC/MC/PC35B
1.02 1.03 0.93
PV8*C16
FC/MC/PC35C
1.02 1.03 0.93
PV8*C20
FC/MC/PC35C
1.01 1.01 0.92
P(C,V)9*B12
FC/MC/PC35B
1.02 1.01 0.93
P(C,V)9*C16
FC/MC/PC35C
1.02 1.02 0.93
PV8*A12
FC/MC/PC38A
1.01 1.01 0.92
PV9*A12
FC/MC/PC38A
1.01 1.01 0.92
PV8*B16
FC/MC/PC43B
1.02 1.03 0.93
PV8*C16
FC/MC/PC43C
1.02 1.03 0.93
PV8*C20
FC/MC/PC43C
1.01 1.01 0.92
P(C,V)9*B12
FC/MC/PC43B
1.02 1.01 0.93
P(C,V)9*C16
FC/MC/PC43C
1.02 1.02 0.93
PV8*B16
HC36
1.02 1.03 0.93
P(C,V)9*B12
HC36
1.02 1.01 0.93
PV8*C16
HC42
1.02 1.03 0.93
PV8*C20
HC42
1.01 1.01 0.92
P(C,V)9*C16
HC42
1.02 1.02 0.93