beautypg.com

York AHP18 User Manual

Page 11

background image

255029-YTG-M-0610

Johnson Controls Unitary Products

11

*

Optional dehumidification humidistat switch contacts open on rise.

Notes:
1. “Y” Terminal on Air Handler Control Board must be connected for full CFM and applications requiring 60 second blower off delay for SEER
enhancement.
2. Move HUM STAT Jumper on AH Control Board to YES/NO position.
3. MODE Jumper on AH control board should be set to HP for heat pumps.
4. To change quantity of heat during HP defrost cycle - Reverse connections at W1 & W2 on Air Handler Control Board.

TYPICAL APPLICATIONS

SINGLE-STAGE COOLING WIRING

THERMOSTAT

AIR HANDLER

BOARD

HEAT PUMP

R

R

R

G

G

Y

W / W1

O

W

O

O

C

X / L

X / L

C

Y / Y2

Y1

Y

W1 66

W2

W1

HUM

COM

HUMIDISTAT *

W2

E

X / L

And Newer UPG Single Stage HP Systems

Single Stage H/P with Standard Demand Defrost Control Board

CONTROL WIRING - AHP or MA Series Air Handler

UPFLOW

DOWNFLOW

HORIZONTAL RIGHT

HORIZONTAL LEFT