Status led during inverter mode –6, Table 4-1, Status led during inverter mode – Xantrex Technology ENERGY HW 1000 User Manual
Page 44

4–6
975-0467-01-01
Status LED During Inverter Mode
The following summarizes the behavior of the Status LED during Inverter
mode.
Table 4-1 Status LED during Inverter Mode
Status LED
Display Screen
Condition
Solid
YELLOW
12.8
(where 12.8 is an
example of battery
voltage)
Select button is pressed to display Input Battery Voltage.
The Input Battery Voltage LED lights up.
Value in display screen is shown as Volts.
11
(where 11 is an
example of current)
Select button is pressed to display Input Current.
The Input Current LED lights up.
Value in display screen is shown as Amps.
0.85
(where 0.85 is an
example of output
power in Kilowatts)
Select button is pressed to display Output Power.
The Output Power LED lights up.
Value in display screen is shown as Kilowatts.
5A
or
15A
or
35A
or
55A
Select button is pressed to display present Charging Current
setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
IN0
or
In1
Select button is pressed to display present Inverter Mode
setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
aL0
or
AL1
Select button is pressed to display present Alarm setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
sdL
or
sdH
Select button is pressed to display present Shutdown setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
E05
through
e07
Warning condition detected while AC output power is still
available.
See
Table 5-1, “Error Codes Displayed on the Display Panel
.