Cascade Connection ([Cascade] Connectors) (DME64N only)

DME64N/DME24N Owner’s Manual

31

Cascade Connection ([Cascade] Connectors) (DME64N only)

The rear-panel [CASCADE] connector can be connected to the [CASCADE] connector on another
DME64N/24N or other compatible device via a dedicated cascade cable for bidirectional transfer of control,
audio, and word clock signals. The communication direction automatically switches to unidirectional when
connecting to a mixer such as the PM5D, or bidirectional when connecting to another DME64N/24N unit.
In the unidirectional mode the audio signal flow is from the [CASCADE OUT] connector to the [CASCADE
IN] connector. In the bidirectional mode signal flow also occurs in the reverse direction via the same cable. The
total number of audio channels that can be connected to a mixer or DME64N/24N unit is 32.
Word clock is continuously output from both the [CASCADE IN] and [CASCADE OUT] connectors, and is
received by the corresponding [CASCADE IN] or [CASCADE OUT] connector on the connected device.
In all cases the [CASCADE OUT] of one device must be connected to the [CASCADE IN] connector of the
other. Do not connect [CASCADE IN] to [CASCADE IN], or [CASCADE OUT] to [CASCADE OUT].

Cascade Connection Example

NOTE

Maximum length by the optional dedicated Cascade cables
Unidirectional Cascade connection: 200m (44.1/48kHz), 100m (88.2/96kHz)
Bidirectional Cascade connection: 100m (44.1/48kHz), 30m (88.2/96kHz)

NOTE

Never create a full cascade loop using only DME64N units!

NOTE

It is also possible to remotely control DME series units from the PM5D via a CASCADE connection. In such cases assign the
nearest DME64N unit to the PM5D as the device group master. When using a DME64N/24N together with the DME
Satellite, you must assign the DME Satellite as the master.
Another method of remotely controlling a DME series from a PM5D is via CobraNet connections to MY16-C or MY16-CII
cards.
All DME series units to be controlled from the PM5D must be in the same device group, and the host address of the device
group master must be set to “2.”

DME64N

DME64N

IN

OUT

PM5D

DME64N

DME64N

IN

OUT

OUT

IN

OUT

IN

Unidirectional Cascade Connection

Bidirectional Cascade Connection

68-pin Half-pitch D-SUB Cable

68-pin Half-pitch D-SUB Cable

68-pin Half-pitch

D-SUB Cable

68-pin Half-pitch

D-SUB Cable