Switch bank 2 (sw2) audible alarm, Ac service rating, Battery size – Xantrex Technology PROSINE PS3.0 User Manual
Page 44
Prosine 2.5/3.0 Installation & Operation Guide
27
Section 3: Configuration
SWITCH BANK 2 (SW2)
Audible Alarm
Switch 1
❃
UP
Audible signals enabled
Ma
x
AC Curre
nt
Draw
DOWN
Audible signals disabled
Switch 2 Not Used
Br
eake
r Ra
ti
n
g
(
A
mp
s
)
AC service rating
Maximum DC
Charging Amps
PS 2.5
PS 3.0
Switch 3
Switch
4
12V
24V
12V
24V
❃
UP
❃
UP
10 A
8 A
55
30
55
30
DOWN
UP
15 A
12A
90
45
90
45
UP
DOWN
20 A
16A
100
55
100
60
DOWN
DOWN
30 A
24A
100
55
120
60
Battery Size
Switch 5, 6, 7, 8
Max DC charging current (amps)
Battery
Prosine 2.5
Prosine 3.0
#5
#6
#7
#8
Capacity
12V
24V
12V
24V
❃
UP
❃
UP
❃
UP
❃
UP
50 Ah
11A
11A
11A
11A
DOWN
UP
UP
UP
75 Ah
25A
25A
25A
25A
UP
DOWN
UP
UP
100 Ah
33A
33A
33A
33A
DOWN
DOWN
UP
UP
150 Ah
50A
50A
50A
50A
UP
UP
DOWN
UP
200Ah
67A
50A
67A
60A
DOWN
UP
DOWN
UP
300 Ah
100A
50A
100A
60A
UP
DOWN
DOWN
UP
400 Ah
100A
50A
120A
60A
DOWN
DOWN
DOWN
UP
500 Ah
100A
50A
120A
60A
UP
UP
UP
DOWN
600 Ah
100A
50A
120A
60A
DOWN
UP
UP
DOWN
700 Ah
100A
50A
120A
60A
UP
DOWN
UP
DOWN
800 Ah
100A
50A
120A
60A
DOWN
DOWN
UP
DOWN
1000 Ah
100A
50A
120A
60A
UP
UP
DOWN
DOWN
1200 Ah
100A
50A
120A
60A
DOWN
UP
DOWN
DOWN
1400 Ah
100A
50A
120A
60A
UP
DOWN
DOWN
DOWN
1700 Ah
100A
50A
120A
60A
DOWN
DOWN
DOWN
DOWN
2000 Ah
or greater
100A
50A
120A
60A