Xantrex Technology PROSINE PS3.0 User Manual
Page 109
Error Code Table
92
Prosine 2.5/3.0 Installation & Operation Guide
195
Internal DC bus voltage is
low in Charge mode
1 There may be a hot to
ground wiring error. A mis-
take made in AC wiring
caused internal traces to
open. Shoring the AC line to
the chassis ground occasion-
ally causes damage espe-
cially if supplied from a 50 A
service with a short cord.
2 Internal fault
1. Contact Xantrex and
return unit for repair.
2. Record the error code
and contact Xantrex.
196
Internal fault
Various. There could be a
fault inside the unit or the
microprocessor is fooled by
some external condition.
Record the error code and
contact Xantrex.
197
Unexpected AC output volt-
age
AC Input Line and Neutral are
reversed.
Check AC Input wiring.
There should be less than
5V RMS between AC Input
Neutral and Earth Ground.
If you measure higher volt-
age from neutral to ground,
then the AC shorepower
source likely has reversed
polarity and requires cor-
rection.
Long and/or loose connec-
tions to the utility/shore-
power can result in a high
neutral voltage as well.
Check connections and
repair as necessary.
198-201
Internal fault
Various. There could be a
fault inside the unit or the
microprocessor is fooled by
some external condition.
Record the error code and
contact Xantrex.
202,203
Relay Contact Fault
One of the relay contacts is
stuck in the closed position.
Record the error code and
contact Xantrex.
204
AC Input Neutral Warning
AC Input Neutral voltage is
greater than 10 V with respect
to Earth Ground.
See Fault Code 197.
205
Internal fault
Various. There could be a
fault inside the unit or the
microprocessor is fooled by
some external condition.
Record the error code and
contact Xantrex.
Error
Code
Description of Fault
Possible Cause
Solution