Prosine 2.5/3.0 Installation & Operation Guide

93

Appendix C: Troubleshooting

206

AC Output voltage too high

1. Some loads, like motors,

can feed power back into
the output of the Prosine.
This may result in a tempo-
rary over-voltage which
may trigger a fault condi-
tion.

2. There is an internal hard-

ware or software fault.

1. Try resetting the unit and

running the load again.
Contact Xantrex if you
find consistent incompati-
bility with a certain type of
load.

2. Record the error code

and contact Xantrex.

207

Internal DC Bus voltage is
low in invert mode.

1. Temporary condition

caused by low battery volt-
age in conjunction with an
overload condition.

2. Internal Fault.

1. Check if battery is OK

(see error code 002). Dis-
connect AC and DC
power to the Prosine.
Reconnect DC and AC
power after 15 minutes. If
the problem persists, con-
tact Xantrex.

2. Record the error code

and contact Xantrex.

Error
Code

Description of Fault

Possible Cause

Solution