S-register descriptions, 6 s-register descriptions – ZyXEL Communications 56K Plus Series User Manual
Page 47
Omni 56K Plus Series User’s Guide
Command Sets 4-19
4.6 S-Register
Descriptions
In most bit-mapped S-registers, the default bit value is 0. Non-0 default values are followed by an
asterisk. In some cases, default values are shown in the reference column preceded by +. Some bits are
reserved for factory use and should not be changed.
S-Register default values may vary depending on the country.
Table 4-15 Basic S-Registers "ATSn=x"
COMMAND
FUNCTION & DESCRIPTION
+REF.
S0=
Sets the number of rings on which the modem will answer. 0 value disables
auto-answer.
+000
S1=
Counts and stores number of rings from an incoming call.
+000
S2=
Defines escape code character, default ‘+’ (43 dec.). A value of 128-255
disables the escape code.
+043
S3=
Defines ASCII Carriage Return.
+013
S4=
Defines ASCII Line Feed.
+010
S5=
Defines ASCII Backspace. A value of 128-255 disables the Backspace key’s
delete function.
+008
S6=
Sets the number of seconds the modem waits before dialing if ‘X0’ or ‘X1’ is
selected. If a setting of ‘X2,’ ‘X7’ is selected, the modem will dial as soon as it
detects a dial tone. This register also sets the time-out interval for the “W” dial
modifier to wait for the dial tone. (See also S41b4)
+003
S7=
Sets duration, in number of seconds modem waits for a carrier.
+060
S8=
Sets duration, in seconds, for pause (,) option in Dial command and pause
between command re-executions for Repeat (>) command.
+002
S9=
Sets duration, in tenths of a second of remote carrier signal before recognition.
(Ignored if in non-FSK or half-duplex operation)
+006
S10=
Sets duration, in tenths of a second, modem waits after loss of carrier before
hanging up.
+007
S11=
Sets duration and spacing, in milliseconds, of dialed Touch-Tones.
+070
Table 4-16 Extended S-Registers "ATSn=x"
COMMAND BIT DEC HEX
FUNCTION
AND
DESCRIPTION
REF.
S13=
bit dec hex Bit-mapped
register.
+000
1
2
2
Capture modem manufacturer information during V.42
handshake, can be displayed at ATI2
stands for ZyXEL connection)
S14=
bit dec hex Bit-mapped
register:
+002
1
0
0
Grant Remote Digital Loop-back test request.
&T4
2
2
Deny Remote Digital Loop-back test request. (Default)
&T5*
S15=
bit dec hex Bit-mapped
register.
+066