beautypg.com

ZyXEL Communications 56K Plus Series User Manual

Page 39

background image

Omni 56K Plus Series User’s Guide

Command Sets 4-11

Table 4-9 Supported Commands (per TIA PN2388 8/20/90)

COMMAND DESCRIPTION VALUE

+FDR

Receive phase C data command; initiates document reception.

+FDT=df,vr,wd, ln

Transmit phase C data command: release the DCE to proceed with
negotiation.

+FET=n

End of page or document command:

More pages; same document.

n=0

End of document; another document follows.

n=1

No more pages or documents.

n=2

Procedure interrupt; another page follows.

n=4

Procedure interrupt; end of document, another document follows.

n=5

Procedure interrupt; end of document.

n=6

+FK

Regular fax abort command.

+FLID="string"

Local ID string parameter.

+FLO=n

Flow control options:

No flow control.

n=0

Set XON/XOFF software flow control.

n=1

Set CTS/RTS hardware flow control.

n=2

+FLPL=n

Document for polling command:

The DTE has no document available for polling.

n=0

Indicate a document available for polling.

n=1

+FMDL? Request

DCE

model.

+FMFR? Request

DCE

manufacturer.

+FMINSP=n

Minimum phase C speed parameter:

2400

bps.

n=0

4800

bps.

n=1

7200

bps.

n=2

9600

bps.

n=3

12000

bps.

n=4

14400

bps.

n=5

+FPHCTO=

DTE Phase C response time-out:
Determine how long the DCE will wait for a command after reaching
the end of data when transmitting in Phase C.
=0 to 255; 100 ms units.

0-255

+FPTS=n

Page transfer status

Received page good.

n=1

Page bad; retrain requested.

n=2

Page good; retrain requested.

n=3