York SPLIT-SYSTEM YHJF18 THRU 60 User Manual
Page 9
510667-YTG-B-0509
Johnson Controls Unitary Products
9
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
YHJF36S41S1
T*(8,L)X*A12
FC/MC/PC37A
36.0
3.80
2.78
24.6
2.54
2.84
8.50
T*(8,L)X*B12
FC/MC/PC43B
36.0
3.80
2.78
24.6
2.54
2.84
8.50
T*(8,L)X*C16
FC/MC/PC43C
36.0
3.78
2.79
24.0
2.56
2.75
9.00
T*(8,L)X*C20
FC/MC/PC43C
36.0
3.88
2.72
24.4
2.60
2.75
9.00
T*9X*B12
FC/MC/PC43B
36.0
3.80
2.78
24.6
2.54
2.84
8.50
T*9X*C16
FC/MC/PC43C
36.0
3.82
2.76
24.4
2.56
2.79
8.50
T*9X*C20
FC/MC/PC43C
36.0
3.74
2.82
24.2
2.52
2.81
8.50
Y*(8,L)C*C16
FC/MC/PC43C
36.0
3.72
2.84
24.4
2.50
2.86
8.50
Y*(8,L)C*C20
FC/MC/PC43C
36.0
3.74
2.82
24.2
2.52
2.81
8.50
(Y*9C/T*9V)*C16
FC/MC/PC43C
36.0
3.76
2.81
24.6
2.52
2.86
8.50
(Y*9C/T*9V)*C20
FC/MC/PC43C
36.0
3.70
2.85
24.4
2.50
2.86
8.50
YHJF42S41S1
T*(8,L)X*C16
FC/MC62D
40.5
4.06
2.92
26.0
2.78
2.74
9.00
T*(8,L)X*C20
FC/MC62D
41.0
4.08
2.94
26.2
2.78
2.76
9.00
T*9X*C16
FC/MC62D
41.0
3.98
3.02
26.2
2.72
2.82
9.00
T*9X*C20
FC/MC62D
40.5
4.02
2.95
26.2
2.74
2.80
9.00
T*9X*D20
FC/MC62D
40.5
4.02
2.95
26.0
2.76
2.76
9.00
Y*(8,L)C*C16
FC/MC62D
41.0
3.96
3.03
26.4
2.70
2.86
9.00
Y*(8,L)C*C20
FC/MC62D
41.0
4.00
3.00
26.2
2.74
2.80
9.00
(Y*9C/T*9V)*C16
FC/MC62D
41.5
3.86
3.15
26.6
2.64
2.95
9.00
(Y*9C/T*9V)*C20
FC/MC62D
41.0
3.90
3.08
26.4
2.68
2.89
9.00
(Y*9C/T*9V)*D20
FC/MC62D
41.0
3.94
3.05
26.4
2.70
2.86
9.00
YHJF48S41S1
T*(8,L)X*C16
FC/MC62D
48.0
3.78
3.72
32.0
2.56
3.66
9.00
T*(8,L)X*C20
FC/MC62D
48.0
3.80
3.70
31.8
2.58
3.61
9.00
T*9X*C16
FC/MC62D
48.0
3.76
3.74
32.0
2.56
3.66
9.00
T*9X*C20
FC/MC62D
48.0
3.80
3.70
32.0
2.58
3.63
9.00
T*9X*D20
FC/MC62D
48.0
3.76
3.74
32.0
2.56
3.66
9.00
Y*(8,L)C*C20
FC/MC62D
48.0
3.76
3.74
32.0
2.56
3.66
9.00
(Y*9C/T*9V)*C16
FC/MC62D
48.0
3.72
3.78
32.2
2.54
3.71
9.00
(Y*9C/T*9V)*C20
FC/MC62D
48.0
3.68
3.82
32.4
2.50
3.80
9.00
(Y*9C/T*9V)*D20
FC/MC62D
48.0
3.72
3.78
32.2
2.52
3.74
9.00
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
MODEL
FURNACE
MODEL
COIL
1
MODEL
ARI HEATING
2
47
F
17
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD