beautypg.com

York SPLIT-SYSTEM YHJF18 THRU 60 User Manual

Page 9

background image

510667-YTG-B-0509

Johnson Controls Unitary Products

9

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.

YHJF36S41S1

T*(8,L)X*A12

FC/MC/PC37A

36.0

3.80

2.78

24.6

2.54

2.84

8.50

T*(8,L)X*B12

FC/MC/PC43B

36.0

3.80

2.78

24.6

2.54

2.84

8.50

T*(8,L)X*C16

FC/MC/PC43C

36.0

3.78

2.79

24.0

2.56

2.75

9.00

T*(8,L)X*C20

FC/MC/PC43C

36.0

3.88

2.72

24.4

2.60

2.75

9.00

T*9X*B12

FC/MC/PC43B

36.0

3.80

2.78

24.6

2.54

2.84

8.50

T*9X*C16

FC/MC/PC43C

36.0

3.82

2.76

24.4

2.56

2.79

8.50

T*9X*C20

FC/MC/PC43C

36.0

3.74

2.82

24.2

2.52

2.81

8.50

Y*(8,L)C*C16

FC/MC/PC43C

36.0

3.72

2.84

24.4

2.50

2.86

8.50

Y*(8,L)C*C20

FC/MC/PC43C

36.0

3.74

2.82

24.2

2.52

2.81

8.50

(Y*9C/T*9V)*C16

FC/MC/PC43C

36.0

3.76

2.81

24.6

2.52

2.86

8.50

(Y*9C/T*9V)*C20

FC/MC/PC43C

36.0

3.70

2.85

24.4

2.50

2.86

8.50

YHJF42S41S1

T*(8,L)X*C16

FC/MC62D

40.5

4.06

2.92

26.0

2.78

2.74

9.00

T*(8,L)X*C20

FC/MC62D

41.0

4.08

2.94

26.2

2.78

2.76

9.00

T*9X*C16

FC/MC62D

41.0

3.98

3.02

26.2

2.72

2.82

9.00

T*9X*C20

FC/MC62D

40.5

4.02

2.95

26.2

2.74

2.80

9.00

T*9X*D20

FC/MC62D

40.5

4.02

2.95

26.0

2.76

2.76

9.00

Y*(8,L)C*C16

FC/MC62D

41.0

3.96

3.03

26.4

2.70

2.86

9.00

Y*(8,L)C*C20

FC/MC62D

41.0

4.00

3.00

26.2

2.74

2.80

9.00

(Y*9C/T*9V)*C16

FC/MC62D

41.5

3.86

3.15

26.6

2.64

2.95

9.00

(Y*9C/T*9V)*C20

FC/MC62D

41.0

3.90

3.08

26.4

2.68

2.89

9.00

(Y*9C/T*9V)*D20

FC/MC62D

41.0

3.94

3.05

26.4

2.70

2.86

9.00

YHJF48S41S1

T*(8,L)X*C16

FC/MC62D

48.0

3.78

3.72

32.0

2.56

3.66

9.00

T*(8,L)X*C20

FC/MC62D

48.0

3.80

3.70

31.8

2.58

3.61

9.00

T*9X*C16

FC/MC62D

48.0

3.76

3.74

32.0

2.56

3.66

9.00

T*9X*C20

FC/MC62D

48.0

3.80

3.70

32.0

2.58

3.63

9.00

T*9X*D20

FC/MC62D

48.0

3.76

3.74

32.0

2.56

3.66

9.00

Y*(8,L)C*C20

FC/MC62D

48.0

3.76

3.74

32.0

2.56

3.66

9.00

(Y*9C/T*9V)*C16

FC/MC62D

48.0

3.72

3.78

32.2

2.54

3.71

9.00

(Y*9C/T*9V)*C20

FC/MC62D

48.0

3.68

3.82

32.4

2.50

3.80

9.00

(Y*9C/T*9V)*D20

FC/MC62D

48.0

3.72

3.78

32.2

2.52

3.74

9.00

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.

3. Variable speed furnaces have B.O.D (Blower on Delay) standard.

HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)

MODEL

FURNACE

MODEL

COIL

1

MODEL

ARI HEATING

2

47

F

17

F

HSPF

MBH

COP

KW

MBH

COP

KW

STD