Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
YHJF18S41S1
EVAPORATOR COIL MODEL NO
AHX30
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
450
600
750
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
21.1
4.1
1.3
22.2
4.5
1.2
23.3
4.9
1.1
70
20.5
3.6
1.5
21.6
4.0
1.4
22.6
4.3
1.3
80
19.9
3.2
1.6
20.9
3.5
1.5
21.9
3.9
1.4
47
60
18.6
3.8
1.3
19.2
4.0
1.2
19.8
4.2
1.1
70
17.7
3.3
1.4
18.4
3.5
1.3
19.1
3.7
1.2
80
16.8
2.8
1.6
17.6
3.1
1.5
18.4
3.3
1.4
40
60
16.7
3.4
1.3
17.3
3.6
1.2
17.9
3.8
1.1
70
16.1
3.0
1.4
16.8
3.2
1.3
17.4
3.4
1.2
80
15.6
2.7
1.5
16.3
2.9
1.4
17.0
3.1
1.3
30
60
14.6
3.1
1.2
15.1
3.2
1.2
15.5
3.4
1.1
70
14.2
2.7
1.4
14.6
2.9
1.3
15.0
3.0
1.2
80
13.7
2.4
1.5
14.1
2.5
1.4
14.4
2.6
1.3
17
60
11.7
2.6
1.2
12.0
2.6
1.1
12.3
2.7
1.1
70
11.2
2.2
1.3
11.6
2.3
1.2
11.9
2.4
1.2
80
10.8
2.0
1.5
11.1
2.0
1.4
11.5
2.1
1.3
10
60
10.1
2.3
1.1
10.3
2.3
1.1
10.4
2.3
1.0
70
9.6
1.9
1.3
9.9
2.0
1.2
10.2
2.1
1.2
80
9.1
1.7
1.4
9.5
1.8
1.4
9.9
1.9
1.3
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
AV*36
–
1.00
1.03
0.97
MV12B
FC/MC35B
1.00
0.97
1.03
MV12B
FC/MC43B
1.00
1.01
0.99
Furnace
Coil
MBH
KW
COP
T*(8,L)X*A12
FC/MC/PC32A
0.99
0.99
1.00
Y*(8,L)C*A12
FC/MC/PC32A
1.00
0.97
1.03
Y*(8,L)C*B12
FC/MC/PC35B
1.00
0.99
1.01
Y*(8,L)C*C16
FC/MC/PC35C
1.00
0.98
1.02
(Y*9C/T*9V)*B12
FC/MC/PC35B
1.00
0.98
1.02
(Y*9C/T*9V)*C16
FC/MC/PC35C
1.00
0.99
1.01
Y*(8,L)C*A12
FC/MC/PC37A
1.00
1.01
0.99
Y*(8,L)C*B12
FC/MC/PC43B
1.00
0.98
1.02