York SPLIT-SYSTEM YHJF18 THRU 60 User Manual
Page 23
510667-YTG-B-0509
Johnson Controls Unitary Products
23
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
YHJF36S41S1
EVAPORATOR COIL MODEL NO
AHX36
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1000
1200
1400
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
47.2
4.2
2.9
47.9
4.4
2.7
48.6
4.6
2.6
70
46.3
3.7
3.3
46.8
3.9
3.1
47.3
4.1
2.9
80
45.3
3.3
3.7
45.6
3.4
3.4
46.0
3.6
3.2
47
60
40.0
3.7
2.8
40.4
3.8
2.7
40.9
4.0
2.5
70
39.5
3.3
3.2
39.8
3.4
3.0
40.1
3.5
2.8
80
38.9
2.9
3.5
39.2
3.0
3.3
39.4
3.2
3.2
40
60
36.8
3.5
2.7
37.0
3.6
2.6
37.2
3.7
2.5
70
36.3
3.1
3.1
36.4
3.2
2.9
36.6
3.3
2.8
80
35.7
2.7
3.5
35.9
2.8
3.3
36.0
2.9
3.1
30
60
31.9
3.1
2.7
32.0
3.1
2.5
32.1
3.2
2.4
70
31.5
2.7
3.1
31.6
2.8
2.9
31.7
2.9
2.7
80
31.0
2.4
3.4
31.2
2.5
3.2
31.4
2.6
3.1
17
60
25.3
2.6
2.5
25.4
2.6
2.4
25.4
2.6
2.3
70
24.2
2.2
2.9
24.7
2.3
2.8
25.2
2.3
2.6
80
23.1
1.9
3.2
24.1
2.0
3.1
25.0
2.1
3.0
10
60
21.6
2.3
2.3
20.9
2.3
2.3
20.2
2.2
2.2
70
21.4
2.0
2.7
20.3
2.0
2.6
19.2
1.9
2.5
80
21.1
1.8
3.1
19.6
1.7
2.9
18.2
1.6
2.7
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
AHX42
–
1.00
1.01
0.99
AV*36
–
1.00
0.99
1.01
F6FP042
–
1.00
1.02
0.98
MV12B
FC/MC43B
1.00
0.98
1.02
MV16C
FC/MC43C
1.00
0.98
1.02
Furnace
Coil
MBH
KW
COP
T*(8,L)X*A12
FC/MC/PC37A
1.00
1.00
1.00
T*(8,L)X*B12
FC/MC/PC43B
1.00
1.00
1.00
T*(8,L)X*C16
FC/MC/PC43C
1.00
0.99
1.01
T*(8,L)X*C20
FC/MC/PC43C
1.00
1.02
0.98
T*9X*B12
FC/MC/PC43B
1.00
1.00
1.00
T*9X*C16
FC/MC/PC43C
1.00
1.01
0.99
T*9X*C20
FC/MC/PC43C
1.00
0.98
1.02
Y*(8,L)C*C16
FC/MC/PC43C
1.00
0.98
1.02
Y*(8,L)C*C20
FC/MC/PC43C
1.00
0.98
1.02
(Y*9C/T*9V)*C16
FC/MC/PC43C
1.00
0.99
1.01
(Y*9C/T*9V)*C20
FC/MC/PC43C
1.00
0.97
1.03