5 Operating the XPower Inverter
This section explains how to operate the XPower 175 Plus,
XPower 400 Plus and XPower 700 Plus most efficiently.
Operating Conditions and Guidelines
This section describes normal operation as well as conditions that
trigger an alarm or automatically shut down the XPower.
Normal Operation
When you connect the inverter to the vehicle’s
cigarette lighter or directly to the 12 volt outlet and turn on the
On/Off switch, the green
POWER
light illuminates and AC
power is available at the outlets. You can now plug in your AC
products and switch them on one at a time.
Low Battery Alarm and Shutdown
As the battery discharges, its
voltage decreases. When the XPower senses that the voltage at its
DC input has dropped to 10.7 volts, it sounds an alarm. If you
ignore the alarm, and the DC input voltage drops below 10.0
volts, the inverter shuts down all loads to save the battery from
further discharge. The red
FAULT
light comes on.