Nominal rating – York DH 036 User Manual
Page 17

036-21506-003-C-0405
Unitary Products Group
17
TABLE 5: DH048 COOLING CAPACITIES (4 TON)
CFM
WB °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
59
3.3
46
40
34
28
23
-
-
55
3.5
43
37
32
26
20
-
-
67
53
3.2
53
49
43
38
32
26
21
49
3.4
49
47
41
35
30
24
62
47
3.2
47
47
47
42
36
30
25
44
3.4
44
44
44
38
32
26
57
47
3.1
47
47
47
41
35
29
24
43
3.3
43
43
43
37
31
26
72
58
3.3
42
37
32
27
22
-
-
54
3.5
40
35
30
25
20
-
-
67
53
3.2
50
46
41
35
30
25
20
48
3.4
47
44
39
33
28
23
62
47
3.2
47
47
46
41
36
31
26
43
3.4
43
43
43
38
33
28
57
46
3.1
46
46
46
41
35
30
25
42
3.3
42
42
42
37
32
27
72
57
3.3
39
34
30
25
21
-
-
53
3.5
37
33
28
23
19
-
-
67
52
3.2
47
42
38
33
29
24
19
48
3.4
45
41
36
32
27
22
62
46
3.2
46
46
45
41
36
32
27
42
3.4
42
42
43
39
34
30
57
45
3.1
45
45
45
40
36
31
27
41
3.3
41
41
41
37
32
28
72
54
3.2
35
31
27
23
19
-
-
51
3.5
34
30
26
22
17
-
-
67
49
3.1
43
39
35
31
27
23
19
45
3.4
41
37
33
29
25
21
62
43
3.1
43
43
42
38
34
30
26
40
3.4
40
40
40
36
32
28
57
43
3.1
43
43
41
37
33
29
25
39
3.3
39
39
38
34
30
26
72
51
3.2
32
29
25
22
18
-
-
48
3.5
30
27
23
20
16
-
-
67
46
3.1
39
35
32
28
25
21
18
42
3.5
37
34
30
27
23
20
62
41
3.1
41
41
38
35
31
28
24
38
3.4
38
38
36
33
29
26
57
40
3.0
40
40
38
34
31
27
24
37
3.4
37
37
35
31
28
24
CFM
WB °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
50
3.8
41
35
30
24
18
-
-
45
4.0
39
33
28
22
16
-
-
67
45
3.7
45
44
39
33
27
22
16
40
4.0
40
40
37
31
25
20
62
39
3.6
39
39
39
34
28
22
17
35
3.8
35
35
35
30
24
18
57
39
3.6
39
39
39
33
27
22
16
35
3.8
35
35
35
29
23
18
72
50
3.8
38
33
28
23
18
-
-
45
4.0
36
31
26
21
16
-
-
67
44
3.7
44
41
36
31
26
21
16
40
4.0
40
39
34
29
24
19
62
39
3.6
39
39
40
35
30
25
20
35
3.9
35
35
37
32
27
22
57
38
3.6
38
38
38
33
28
23
18
34
3.8
34
34
34
29
24
19
72
49
3.8
35
31
26
21
17
-
-
45
4.1
33
29
24
20
15
-
-
67
44
3.7
43
39
34
30
25
20
16
40
4.1
40
37
32
27
23
18
62
39
3.6
39
39
41
37
32
27
23
35
3.9
35
35
39
34
30
25
57
38
3.6
38
38
38
33
29
24
19
34
3.8
34
34
34
30
25
20
72
47
3.8
32
28
24
20
16
-
-
43
4.0
30
26
22
18
14
-
-
67
42
3.7
39
35
31
27
23
19
15
38
4.0
37
34
29
25
21
17
62
37
3.6
37
37
38
33
29
25
21
33
3.8
33
33
35
31
27
23
57
36
3.5
36
36
35
31
27
23
18
33
3.7
33
33
31
27
23
19
72
44
3.7
29
25
22
18
15
-
-
41
3.9
27
24
20
17
13
-
-
67
40
3.7
36
32
29
25
21
18
14
36
3.9
34
30
27
23
20
16
62
35
3.6
35
35
34
30
27
23
20
32
3.8
32
32
32
28
25
21
57
34
3.5
34
34
32
28
25
21
18
31
3.7
31
31
29
25
22
18
NOMINAL RATING
1200
1400
85°F
POWER
INPUT
2
kW
95°F
SENSIBLE CAPACITY
1
ENTERING DRY BULB, °F
2000
1800
1600
SENSIBLE CAPACITY
1
ENTERING DRY BULB, °F
AIR ON
EVAPORATOR
COIL
TEMPERATURE OF AIR ON CONDENSER COIL
1050
POWER
INPUT
2
kW
ENTERING DRY BULB, °F
ENTERING DRY BULB, °F
AIR ON
EVAPORATOR
COIL
TEMPERATURE OF AIR ON CONDENSER COIL
105°F
115°F
SENSIBLE CAPACITY
1
SENSIBLE CAPACITY
1
900
TOTAL
CAP.
1
MBH
POWER
INPUT
2
kW
TOTAL
CAP.
1
MBH
TOTAL
CAP.
1
MBH
POWER
INPUT
2
kW
TOTAL
CAP.
1
MBH
1500
1350
1200
1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower from the SUPPLY AIR BLOWER PERFORMANCE
Tables, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor
power input is 0.36kW. Refer to SUPPLY AIR BLOWER PERFORMANCE Tables for the kW of the supply air blower motor.