York YHJF18 User Manual
Page 7
510667-YTG-A-0409
Johnson Controls Unitary Products
7
\
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - With Air Handler
UNIT
MODEL*
AIR
HANDLER
COIL
1
MODEL
ARI HEATING
2
47
F
17
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
14.5 SEER HP WITH MV - VARIABLE SPEED
YHJF18S41S1
MV12B
FC/MC35B
18.0
3.76
1.40
11.0
2.48
1.30
8.50
MV12B
FC/MC43B
18.0
3.90
1.35
10.9
2.56
1.25
8.50
YHJF24S41S1
MV12B
FC/MC35B
22.2
3.68
1.77
14.9
2.46
1.77
8.50
MV12B
FC/MC43B
22.2
3.82
1.70
14.9
2.54
1.72
8.50
YHJF30S41S1
MV12B
FC/MC43B
30.0
3.88
2.27
18.8
2.68
2.06
9.00
MV16C
FC/MC43C
30.0
3.92
2.24
18.8
2.70
2.04
9.00
YHJF36S41S1
MV12B
FC/MC43B
36.0
3.74
2.82
24.4
2.52
2.84
8.20
MV16C
FC/MC43C
36.0
3.74
2.82
24.2
2.52
2.81
9.00
YHJF42S41S1
MV20D
FC/MC62D
40.5
4.02
2.95
26.0
2.76
2.76
9.00
YHJF48S41S1
MV20D
FC/MC62D
48.0
3.82
3.68
31.8
2.60
3.58
9.00
14.5 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
YHJF18S41S1
AV*36
–
18.0
3.98
1.33
10.8
2.62
1.21
8.50
YHJF24S41S1
AV*36
–
22.0
3.70
1.74
14.8
2.50
1.73
8.50
YHJF30S41S1
AV*36
–
29.8
3.98
2.19
18.6
2.74
1.99
9.00
YHJF36S41S1
AV*36
–
36.0
3.78
2.79
24.2
2.54
2.79
9.00
14.5 SEER HP WITH AHP / SHP / AHX / F*FP
YHJF18S41S1
AHX30
–
18.0
3.88
1.36
10.9
2.52
1.27
8.50
YHJF24S41S1
AHX30
–
22.2
3.64
1.79
13.7
2.42
1.66
8.50
F6FP030
–
22.2
3.64
1.79
15.1
2.42
1.83
8.20
F6FP036
–
22.2
3.68
1.77
15.0
2.46
1.79
8.50
AHX36
–
22.4
3.70
1.77
15.1
2.46
1.80
8.50
YHJF30S41S1
AHX36
–
30.0
4.00
2.20
18.7
2.76
1.99
9.00
F6FP042
–
30.0
4.00
2.20
18.7
2.76
1.99
9.00
YHJF36S41S1
AHX36
–
36.0
3.82
2.76
24.2
2.56
2.77
9.00
AHX42
–
36.0
3.84
2.75
22.2
2.56
2.54
9.00
F6FP042
–
36.0
3.88
2.72
24.4
2.60
2.75
9.00
YHJF42S41S1
AHX60
–
40.5
4.00
2.97
26.0
2.74
2.78
9.00
F6FP060
–
41.0
4.04
2.97
26.2
2.74
2.80
9.00
YHJF48S41S1
AHX60
–
48.0
3.82
3.68
31.6
2.60
3.56
9.00
F6FP060
–
48.0
3.82
3.68
31.6
2.60
3.56
9.00
See notes below.
HEATING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR
HANDLER
COIL
1
MODEL
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @ 47
47 OD
17 OD
14.5 SEER HP WITH MV - VARIABLE SPEED
YHJF60S41S1
MV20D
FC/MC62D
1
1160
43.0
–
–
–
2
1855
57.0
40.5
9.00
3.66
2
1160
54.9
39.0
8.85
3.04
14.5 SEER HP WITH AHX
YHJF60S41S1
AHX60
–
1
1160
43.1
–
–
–
2
1855
58.0
40.0
9.00
3.72
2
1170
57.5
40.0
8.90
3.24
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.