All dimensions are in inches. They are subject to change with-
out notice. Certified dimensions will be provided upon request.

Physical and Electrical Data

MODEL

YHJF18

S41S1

YHJF24

S41S1

YHJF30

S41S1

YHJF36

S41S1

YHJF42

S41S1

YHJF48

S41S1

YHJF60

S41S1

Unit Supply Voltage

208-230V, 1

 60Hz

Normal Voltage Range

1

187 to 252

Minimum Circuit Ampacity

11.9

17.6

17.3

23.7

26.1

28.8

35.3

Max. Overcurrent Device Amps

2

20

30

30

40

45

50

60

Min. Overcurrent Device Amps

3

15

20

20

25

30

30

40

Compressor Type

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

Compressor Amps

Rated Load

9.0

13.4

12.8

17.9

19.8

28.8

35.3

Locked Rotor

48.0

58.3

64.0

96.7

115.0

115.0

118.0

Crankcase Heater

No

No

No

No

No

No

No

Fan Motor Amps

Rated Load

0.7

0.8

1.3

1.3

1.3

1.3

1.3

Fan Diameter Inches

24

22

24

24

24

24

24

Fan Motor

Rated HP

1/10

1/8

1/4

1/4

1/4

1/4

1/4

Nominal RPM

825

1075

850

850

850

850

850

Nominal CFM

2000

2000

3900

3900

3900

3800

3800

Coil

Face Area Sq. Ft.

15.72

19.17

23.58

23.58

23.58

23.58

23.58

Rows Deep

1

1

1

1

1

2

2

Fin / Inches

22

22

22

22

22

18

18

Liquid Line Set OD (Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

3/4

3/4

3/4

3/4

7/8

7/8

1-1/8

Unit Charge (Lbs. - Oz.)

4

6 – 15

7 – 14

9 – 14

10 – 9

10 – 9

14 – 2

14 – 2

Charge Per Foot, Oz.

0.62

0.62

0.62

0.62

0.67

0.67

0.75

Operating Weight Lbs.

145

145

176

193

198

248

290

1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add

or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

B

C

A

Unit

Model

Dimensions

(Inches)

Refrigerant Connection

Service Valve Size

A

1

1. Including Fan Guard.

B

C

Liquid

Vapor

18

28

34

34

3/8”

3/4”

24

40

29

29

30

40

34

34

36

40

34

34

42

40

34

34

7/8”

48

40

34

34

60

40

34

34