Johnson Controls Unitary Products

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.

— = Not Applicable.

ACCESSORIES

Refer to Price Manual for specific model numbers.

Start Assist Kit - Provides starting torque for low voltage appli-
cations.

Blower Time Delay - Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.

Low Temperature Cutout (2LT06700224) - Prevents heat

pump operation below -1

°F ambient temperature.

Thermal Expansion Valve Kit - 1TVM4 Series TXV kit used
when required.

Outdoor Thermostat (2TD06700124) - Provides additional
staging of supplemental electric heat.

Room Thermostats - A wide selection of matching thermostats
is available to provide features required for any installation.

* For the most current accessory information, refer to the price
book or consult factory.

HEATING CAPACITY - With High Efficiency Motor Furnaces

UNIT

MODEL

VARIABLE SPEED

FURNACE MODEL

COIL

MODEL

1

HEATING

2

STAGE

RATED

CFM

NET MBH

HSPF

COP @ 47

47 OD

17 OD

14.5 SEER HP WITH VARIABLE SPEED FURNACES

3

YHJF60S41S1

T*(8,L)X*C20

FC/MC62D

1

835

42.0

2.98

2

1665

57.0

39.5

9.00

3.64

2

835

56.5

38.5

8.85

2.62

T*9X*C20

FC/MC62D

1

1220

43.5

3.38

2

1595

57.0

40.0

9.00

3.58

2

1220

55.6

39.0

8.60

3.08

T*9X*D20

FC/MC62D

1

1240

43.5

3.42

2

1645

57.0

40.0

9.00

3.60

2

1240

55.6

39.0

8.65

3.10

Y*(8,L)(C,V)*C20

FC/MC62D

1

1015

42.5

3.20

2

1615

57.0

40.0

9.00

3.58

2

1015

55.6

39.0

8.75

2.86

Y*9(C,V)*C20

FC/MC62D

1

1040

43.0

3.20

2

1655

57.0

40.5

9.00

3.54

2

1040

54.9

39.0

8.70

2.88

Y*9(C,V)*D20

FC/MC62D

1

1085

43.0

3.26

2

1630

57.0

40.0

9.00

3.54

2

1085

55.6

39.0

8.65

2.94

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.

3. Variable speed furnaces have B.O.D (Blower on Delay) standard.