Figure 5 : unit dimensions, Table 19: unit clearances, Detail a – York PREDATORTM MAGNUM DJ 150 User Manual

Page 18: Detail b, Detail c

background image

036-21484-001-B-0103

18

Unitary Products

FIGURE 5 : UNIT DIMENSIONS

50-3/4

4-1/4

59

30-3/16

24-3/16

17-3/16

27

89

11-1/2

LEFT

FRONT

For Drain Dimensions

See Detail C

See Detail A

119-7/16

Power

Entry

2-1/2

Con-

venience

Outlet

For

Baserail

Dimensions

See

Detail B

6-3/16

30-11/32

Control

Entry 7/8

Con-

venience

Outlet

Power

Entry

7/8

TABLE 19: UNIT CLEARANCES

Top

*

*

Units must be installed outdoors. Overhanging structure or
shrubs should not obstruct condenser air discharge outlet.

72”

Right

12”

Front

36”

Left

36”

Rear

To remove the slide-out drain pan, a rear clearance of 60” is
required. If space is unavailable, the drain pan can be
removed through the front by separating the corner wall.

36”

Bottom

Units may be installed on combustible floors made from
wood or class A, B or C roof covering materials.

0”

5 - 1 / 4

B a s e

P a n

1 7 - 1 3 / 1 6

V i e w o f W a l l A c r o s s f r o m C o i l

G a s P i p e I n l e t

DETAIL A

3 - 3 / 4

3 - 9 / 1 6

2 - 3 / 8

DETAIL B

5 - 3 / 8

DETAIL C