beautypg.com

4 resetting the bridge to its default settings, Esetting the, Ridge to – Zoom ADSL Modem BRIDGE 5515 User Manual

Page 11: Efault, Ettings

background image

Chapter 2: System Administration

11

Note: We strongly recommend that you change the administrator

password to safeguard the security of your network.

2.4 Resetting the Bridge to Its Default

Settings

If you have changed the system settings on your Bridge and want
to restore them to the factory default settings, you can do so in one

of two ways: You can perform a software reset or a “hard” reset.

Note: The unit’s default IP address is http://10.0.0.2.

If you can open your Web browser and access your Bridge’s user
interface, initiate a software reset:

From the Advanced Setup page, under Administration, click
Reset to Default. You will be prompted to click the Write

Settings to Flash and Reboot button. Once this process is
complete, your unit is reset to its factory settings. Click on any

of the icons at the top of page to continue.

If you lose your link to the unit and cannot communicate with it
via the Web browser, initiate a hard reset.

Using a paper clip, press the RESET button on the unit’s back
panel. While holding in this button, count to five, and then

release the button. The unit’s LINK light will turn off and

then it will blink slowly, about once per second. You are now

guaranteed that all system settings are set to the unit’s factory

defaults.