York B1HH018 User Manual
Page 8
8
Unitary Products Group
66297-YIM-C-0205
INDOOR DB
TEMPERATURE,
°
F
HEATING SUPERHEAT AT COMPRESSOR SUCTION,
°
F
-10
0
10
20
30
40
50
60
55
4.4
4.4
4.6
4.9
5.6
7.1
10.2
16.6
70
—
—
—
—
—
—
5.9
12.3
80
—
—
—
—
—
—
—
9.3
TABLE 9 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 800 CFM (B1HH024)
TABLE 8 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 800 CFM (B1HH024)
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
18.8
20.7
22.6
24.5
26.4
28.3
30.2
30.6
31.0
31.4
31.8
70
15.7
17.5
19.3
21.1
22.9
24.7
26.5
27.5
28.6
29.7
30.8
75
12.5
14.2
15.9
17.6
19.3
21.0
22.7
24.5
26.2
28.0
29.7
80
9.4
11.0
12.6
14.2
15.8
17.4
19.0
21.4
23.8
26.3
28.7
85
6.2
7.7
9.2
10.7
12.2
13.7
15.2
18.3
21.4
24.6
27.7
90
—
—
5.9
7.2
8.7
10.1
11.5
15.3
19.1
22.9
26.7
95
—
—
—
—
5.1
6.4
7.7
12.2
16.7
21.1
25.6
100
—
—
—
—
—
5.3
6.2
10.0
13.9
17.7
21.5
105
—
—
—
—
—
—
—
7.9
11.1
14.2
17.4
110
—
—
—
—
—
—
—
5.8
8.3
10.8
13.3
115
—
—
—
—
—
—
—
—
5.5
7.3
9.2
INDOOR DB
TEMPERATURE,
°
F
OUTDOOR TEMPERATURE,
°
F
-10
0
10
20
30
40
50
60
55
3.1
3.5
4.0
4.7
5.8
7.3
9.4
12.4
70
—
—
—
—
3.5
5.0
7.1
10.1
80
—
—
—
—
—
3.6
5.7
8.7
TABLE 6 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 600 CFM (B1HH018)
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
5.5
5.8
6.1
6.4
6.7
7.0
7.3
13.0
18.7
24.5
30.2
70
—
5.1
5.5
5.9
6.3
6.7
7.1
12.4
17.8
23.1
28.5
75
—
—
—
5.4
5.8
6.3
6.8
11.8
16.8
21.8
26.8
80
—
—
—
—
5.4
6.0
6.6
11.2
15.8
20.5
25.1
85
—
—
—
—
—
5.6
6.3
10.6
14.9
19.1
23.4
90
—
—
—
—
—
5.3
6.1
10.0
13.9
17.8
21.7
95
—
—
—
—
—
—
5.8
9.4
12.9
16.5
20.0
100
—
—
—
—
—
—
—
7.9
11.0
14.1
17.2
105
—
—
—
—
—
—
—
6.5
9.1
11.8
14.4
110
—
—
—
—
—
—
—
5.0
7.2
9.4
11.6
115
—
—
—
—
—
—
—
—
5.3
7.1
8.8
TABLE 7 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 600 CFM (B1HH018)