CCH CRANKCASE HEATER (OPTIONAL)

PTCR START ASSIST (OPTIONAL DEVICE)

HTR 4

ELECTRIC HEATER (OPT. ACCSSRY: 15, 20 &25 KW ELEC HEAT)

HTR 5 & 6

ELECTRIC HEATER (OPT. ACCSSRY: 20 & 25 KW ELEC HEAT)

K5

RELAY ELECTRIC HEATER, 24 VDC COIL (25 KW ELEC HEAT)

TB2

TERMINAL BLOCK ECM MOTOR "SPEED" CONNECTIONS

K6

RELAY ELECTRIC HEATER, 24 VDC COIL (20 & 25 KW ELEC HEAT)

K7

RELAY LIMIT TRIP, 24 VDC COIL

S5/P5

SOCKET/PLUG CONNECTION ON ID FAN MOTOR, 230V

S4/P4

SOCKET/PLUG CONNECTION ON ID FAN MOTOR, 24V

S3/P3

SOCKET/PLUG CONNECTION ON FAN CONTROL BOARD, LINE VOLTAGE

S2/P2

SOCKET/PLUG CONNECTION ON FAN CONTROL BOARD, LOW VOLTAGE

LS

LIMIT SWITCH, ELECTRIC HEAT (PART OF ELEC HEAT ACCESSORY)

FACTORY WIRING AND DEVICES
OPTIONAL WIRING AND DEVICES
FIELD WIRING

TB1 ON FAN/ELEC HEAT CONTROL BOARD

ROOM THERMOSTAT 24V CONNECTIONS

IDENTIFIED TERMINAL ON RUN CAPACITOR

DS DEFROST SENSOR, CLOSES @ 31 °F, OPENS @ 55 DS DEFROST SENSOR, CLOSES @ 31 °F.

RVS

REVERSING VALVE SOLENOID

RC2

OUTDOOR FAN RUN CAPACITOR (ALTERNATE)

T1

TRANSFORMER, 24V, 40 VA

M1

CONTACTOR, COMPRESSOR & OUTDOOR FAN

LEGEND:

RC1

COMPRESSOR START CAPACITOR (ALTERNATE)

RC1/RC2

COMPRESSOR START & OUTDOOR FAN RUN CAPACITOR

K1

RELAY INDOOR FAN MOTOR

FS

FREEZESTAT SWITCH (OPTIONAL ACCESSORY) OPEN @ 26 °F

LP

LOW PRESSURE SWITCH (OPTIONAL ACCESSORY) OPEN @ 7 PSIG

K2

RELAY ELECTRIC HEATER

K3

RELAY ELECTRIC HEATER, 24 VDC COIL (7.5, 10, 15, 20 & 25 KW ELEC HEAT)

HP

HIGH PRESSURE SWITCH (OPTIONAL ACCESSORY) OPENS @ 380 PSIG

K4

RELAY ELECTRIC HEATER, 24 VDC COIL (15, 20 & 25 KW ELEC HEAT)

HTR 1

ELECTRIC HEATER (OPT. ACCSSRY: ALL KW ELEC HEAT)

HTR 2

ELECTRIC HEATER (OPT. ACCSSRY: 7.5, 10, 15, 20 & 25 KW ELEC HEAT)

HTR 3

ELECTRIC HEATER (OPT. ACCSSRY: 25 KW ELEC HEAT)

F24

FUSE 24V SECONDARY, 5 AMP

F1, F2 FUSES, LINE VOLTAGE - (5, 7.5, 10, 15, 20 & 25 KW ELEC HEAT)

FUSES, LINE VOLTAGE - (7.5, 10, 15, 20 & 25 KW ELEC HEAT)

F5, F6

F3, F4

FUSES, LINE VOLTAGE - (15, 20 & 25 KW ELEC HEAT)

COMPR COMPRESSOR

F7, F8, F9 FUSES, LINE VOLTAGE - (15, 20 & 25 KW ELEC HEAT)

TYPICAL WIRING DIAGRAM LEGEND (See page 18)

TYPICAL WIRING DIAGRAM NOTES (See page 18)

CAUTION - OPEN ALL DISCONNECTS

BEFORE SERVICING THIS UNIT

1. ALL FIELD WIRING TO BE ACCOMPLISHED FOLLOWING CITY,
LOCAL AND/OR NATIONAL CODES IN EFFECT AT TIME OF

INSTALLATION OF THIS UNIT.

2. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER

AND DANGEROUS OPERATION. IF ANY OF THE WIRE AS

SUPPLIED WITH THIS UNIT MUST BE REMOVED, IT MUST BE

REPLACED WITH TYPE 105˚ C, 600V WIRE OR EQUIVALENT
CLEARLY RENUMBERED FOR IDENTIFICATION. VERIFY PROPER

OPERATION AFTER SERVICING.

3. MOTORS ARE INHERENTLY PROTECTED.

4. UNIT FACTORY WIRED FOR 230 VOLT OPERATION. FOR 208
VOLT OPERATION MOVE '108/PR' WIRE FROM 240V TO 208V

ON TRANSFORMER T1.

5. SEE UNIT NAMEPLATE FOR MAXIMUM FUSE SIZE AND MINIMUM

CIRCUIT AMPACITY.

6. IF OPTIONAL SAFETY SWITCH KIT IS INSTALLED,

WIRE 219/BK IS REM0VED.

7. WIRE 204/BR IS REMOVED WHEN ELECTRIC HEAT
IS INSTALLED.

NOTES:

8. SHUNT CONTACT ALSO USED WITH CRANKCASE HEATER. (OPTIONAL)