York B1HH018 User Manual
Page 10
10
Unitary Products Group
66297-YIM-C-0205
TABLE 16 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,600 CFM (B1HH048)
TABLE 15 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,400 CFM (B1HH042)
INDOOR DB
TEMPERATURE,
°
F
HEATING SUPERHEAT AT COMPRESSOR SUCTION,
°
F
-10
0
10
20
30
40
50
60
55
—
—
—
4.0
6.2
9.0
12.5
16.6
70
—
—
—
—
4.4
7.2
10.7
14.8
80
—
—
—
—
—
—
3.3
7.4
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
19.6
22.0
24.4
26.8
29.2
31.6
34.0
34.8
35.6
36.4
37.2
70
19.1
21.5
23.9
26.2
28.6
31.0
33.3
34.2
35.0
35.9
36.7
75
18.7
21.0
23.4
25.7
28.0
30.3
32.7
33.6
34.5
35.4
36.2
80
18.2
20.5
22.8
25.1
27.4
29.7
32.0
32.9
33.9
34.8
35.8
85
17.8
20.0
22.3
24.6
26.8
29.1
31.3
32.3
33.3
34.3
35.3
90
15.5
17.5
19.5
21.5
23.5
25.5
27.5
29.3
31.0
32.8
34.6
95
13.2
14.9
16.7
18.4
20.2
21.9
23.7
26.2
28.8
31.3
33.9
100
10.2
11.7
13.3
14.8
16.4
17.9
19.5
22.4
25.3
28.2
31.2
105
7.2
8.5
9.9
11.2
12.6
13.9
15.3
18.6
21.9
25.1
28.4
110
—
5.3
6.5
7.6
8.8
9.9
11.1
14.7
18.4
22.1
25.7
115
—
—
—
—
—
5.9
6.9
10.9
14.9
19.0
23.0
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
18.5
20.8
23.1
25.4
27.7
30.3
32.3
33.0
33.8
34.6
35.3
70
15.2
17.4
19.6
21.7
23.9
26.1
28.3
29.9
31.6
33.2
34.8
75
11.8
13.9
16.0
18.1
20.2
22.3
24.3
26.8
29.3
31.8
34.3
80
8.5
10.4
12.4
14.4
16.4
18.4
20.4
23.7
27.1
30.4
33.8
85
5.1
7.0
8.9
10.88
12.6
14.5
16.4
20.6
24.8
29.0
33.2
90
5.6
6.6
7.6
8.6
9.7
10.7
11.7
16.4
21.1
25.8
30.5
95
6.1
6.3
6.4
6.5
6.7
6.8
7.0
12.2
17.3
22.5
27.7
100
5.9
6.0
6.1
6.2
6.3
6.4
6.4
10.7
14.9
19.1
23.3
105
5.7
5.7
5.8
5.8
5.8
5.9
5.9
9.2
12.4
15.7
18.9
110
5.5
5.5
5.5
5.4
5.4
5.4
5.4
7.7
10.0
12.2
14.5
115
5.3
5.2
5.1
5.1
5.0
—
—
6.2
7.5
8.8
10.1
INDOOR DB
TEMPERATURE,
°
F
HEATING SUPERHEAT AT COMPRESSOR SUCTION,
°
F
-10
0
10
20
30
40
50
60
55
—
3.0
3.5
4.2
5.1
6.5
8.5
11.3
70
—
—
—
—
3.1
4.5
6.5
9.3
80
—
—
—
—
—
—
—
4.8
TABLE 14 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,400 CFM (B1HH042)
TABLE 17 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,600 CFM (B1HH048)