TABLE 18 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 2,000 CFM (B1HH060)
OUTDOOR
TEMPERATURE,
°
F
INDOOR WB TEMPERATURE,
°
F
55
57
59
61
63
65
67
69
71
73
75
65
—
—
—
5.4
6.8
8.3
9.8
15.5
21.2
27.0
32.7
70
—
—
—
—
6.3
7.8
9.2
14.9
20.6
26.2
31.9
75
—
—
—
—
5.8
7.2
8.6
14.2
19.9
25.5
31.1
80
—
—
—
—
5.3
6.7
8.0
13.6
19.2
24.8
30.3
85
—
—
—
—
—
6.1
7.4
12.9
18.5
24.0
29.6
90
—
—
—
—
—
—
5.8
10.5
15.3
20.0
24.8
95
—
—
—
—
—
—
—
8.2
12.1
16.1
20.0
100
—
—
—
—
—
—
—
6.8
10.0
13.1
16.3
105
—
—
—
—
—
—
—
5.5
7.8
10.2
12.5
110
—
—
—
—
—
—
—
—
5.7
7.2
8.8
115
—
—
—
—
—
—
—
—
—
—
5.0
INDOOR DB
TEMPERATURE,
°
F
HEATING SUPERHEAT AT COMPRESSOR SUCTION,
°
F
-10
0
10
20
30
40
50
60
55
—
—
2.9
3.1
3.7
5.3
9.4
20.0
70
—
—
—
—
—
—
6.6
17.3
80
—
—
—
—
—
—
—
10.2
TABLE 19 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 2,000 CFM (B1HH060)
This manual is related to the following products: