beautypg.com

York YCJF24 User Manual

Page 6

background image

413437-YTG-C-0908

6

Johnson Controls Unitary Products

— = Not applicable.

14.5 SEER AC WITH MV - VARIABLE SPEED (Contimued)

YCJF42S41S1

MV16C 21

FC/MC43C

1400

41.0

30.8

15.00

12.75

MV16C 21

FC/MC48C

1400

41.5

31.2

15.50

13.00

MV20D 24

FC/MC48D

1400

42.0

31.4

15.50

13.00

MV20D 24

FC/MC60D

1400

41.5

31.4

15.50

13.00

MV20D 24

FC/MC62D

1400

42.0

31.4

15.75

13.00

YCJF48S41S1

MV16C 21

FC/MC48C

1600

47.0

33.0

15.25

12.75

MV20D 24

FC/MC48D

1600

47.0

33.0

15.25

12.75

MV20D 24

FC/MC60D

1600

47.0

33.0

15.25

12.75

MV20D 24

FC/MC62D

1600

47.5

33.2

15.25

12.75

YCJF60S41S1

MV20D 24

FC/MC60D

1800

55.0

39.0

14.00

11.95

MV20D 24

FC/MC62D

1800

57.0

39.5

14.50

12.25

14.5 SEER AC WITH AV / SV / F*FV - VARIABLE SPEED

YCJF24S41S1

AV24 17

-

750

25.0

17.5

15.75

13.25

AV36 21

-

750

25.8

18.2

16.50

13.75

YCJF30S41S1

AV36 21

-

1000

30.4

22.4

16.25

13.50

YCJF36S41S1

AV36 21

-

1250

36.2

27.4

15.75

13.25

AV/SV48 24

-

1200

34.4

25.4

15.25

13.00

F4FV060 24

-

1200

34.6

25.6

15.50

13.25

YCJF42S41S1

AV/SV48 24

-

1400

40.0

29.4

14.75

12.50

AV/SV60 24

-

1400

40.0

29.4

14.75

12.50

F4FV060 24

-

1350

40.0

29.6

15.00

12.50

YCJF48S41S1

AV/SV48 24

-

1600

44.5

30.8

14.25

12.00

AV/SV60 24

-

1650

44.0

30.6

14.25

12.00

F4FV060 24

-

1600

44.5

30.6

14.25

12.00

YCJF60S41S1

AV/SV60 24

-

1750

55.0

39.0

14.00

12.00

14.5 SEER AC WITH AHP / SHP / F*FP

YCJF24S41S1

AHP24 17

-

850

24.8

17.4

14.30

12.20

F4FP030 17

-

800

24.8

17.2

14.30

12.20

YCJF30S41S1

AHP36 21

-

1000

29.6

21.4

14.30

12.20

YCJF36S41S1

AHP36 21

-

1200

35.4

26.2

15.00

12.50

F4FP036 21

-

1200

34.2

25.2

14.00

12.00

F4FP040 21

-

1200

34.4

25.0

14.00

12.00

F4FP042 21

-

1200

34.4

25.0

14.00

12.00

F5FP048 24

-

1250

36.4

27.4

16.25

13.50

F5FP060 24

-

1250

34.8

26.0

15.25

13.00

YCJF42S41S1

F5FP048 24

-

1450

42.0

32.0

15.50

13.00

F5FP060 24

-

1500

40.0

29.8

14.75

12.50

YCJF48S41S1

AHP/SHP60 24

-

1600 44.0 30.6

14.20

12.00

F5FP048 24

-

1700

47.5

34.0

15.00

12.75

F5FP060 24

-

1700

44.5

31.2

14.00

12.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

0°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

MODEL

AIR HANDLER

COIL

MODEL

1

COOLING

MODEL

W

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.