York YCJF24 User Manual
Page 2
413437-YTG-C-0908
2
Johnson Controls Unitary Products
All dimensions are in inches. They are subject to change with-
out notice. Certified dimensions will be provided upon request.
Physical and Electrical Data
MODEL
YCJF24S41S1
YCJF30S41S1
YCJF36S41S1
YCJF42S41S1
YCJF48S41S1
YCJF60S41S1
Unit Supply Voltage
208-230V, 1
φ, 60Hz
Normal Voltage Range
1
187 to 252
Minimum
Circuit
Ampacity
16.8 18.4 19.1 23.9 27.9 35.9
Max. Overcurrent Device Amps
2
25 30 30 40 45 60
Min. Overcurrent Device Amps
3
20 20 20 25 30 40
Compressor
Type
Scroll Scroll Scroll Scroll Scroll Scroll
Compressor
Amps
Rated
Load
12.8 14.1 14.1 17.9 21.1 27.5
Locked
Rotor
58 73 77 112
115
135
Crankcase
Heater
No No No No No No
Fan Motor Amps Rated Load
.8
.8
1.5
1.5
1.5
1.5
Fan
Diameter
Inches
22 22 22 24 24 24
Fan Motor
Rated
HP
1/8 1/8 1/4 1/4 1/4 1/4
Nominal
RPM
1075
1075 850 850 850 850
Nominal
CFM
2750 2800 3200 3600 3600 3700
Coil
Face
Area
Sq.
Ft.
13.1 17.4 17.4 20.0 21.4 24.0
Rows
Deep
1 1 1 1 1 1
Fin
/
Inches
23 23 23 23 23 23
Liquid Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line Set OD (Field Installed)
3/4
3/4
3/4
7/8
7/8
1 1/8
Unit Charge (Lbs. - Oz.)
4
3 - 2
3 - 7
3 - 10
4 - 4
4 - 9
5 - 9
Charge
Per
Foot,
Oz.
0.62 0.62 0.62 0.67 0.67 0.75
Operating
Weight
Lbs.
128 130 145 172 180 199
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, smallest matched evaporator coil and 15 feet of refrigerant tubing. For tubing lengths
other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
B
C
A
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
1
1. Including Fan Guard.
B
C
Liquid
Vapor
24
28
29
29
3/8”
3/4”
30
36
29
29
36
36
29
29
42
34
33.6
33.6
7/8”
48
36
33.6
33.6
60
40
33.6
33.6
7/8”
2
2. Adapter fitting required for 1-1/8” line set.