LIMITATIONS

These units must be installed in accordance with the current

edition of the following national and local safety codes:
In USA:

1. National Electrical Code ANSI/NFPA No. 70.

2. Local electric utility requirements.

In Canada:

1. Canadian Electrical Code C22.1.

2. Canadian Installation Codes CAN/CGA-B149.1 and .2.

Refer to Table 1 for Unit Application Data.

If components are to be added to a unit to meet local codes, they

are to be installed at the dealer's and / or the customer's expense.
Size of unit for proposed installation should be based on heat

loss / heat gain calculation made according to the methods of

Air Conditioning Contractors of America (ACCA).

LOCATION

Use the following guidelines to select a suitable location for

these units.

1. Unit is designed for outdoor installation only.

2. Condenser must have an unlimited supply of air. Where a

choice of location is possible, position unit on either north or

east side of building.

3. For ground level installation, a level pad or slab should be

used. The thickness and size of the pad or slab used should

meet local codes and unit weight. Do not tie the slab to the

building foundation.

4. Roof structures must be able to support the weight of the unit

and its options and / or accessories. Unit must be installed on

a solid level roof curb or appropriate angle iron frame.

CAUTION: If a unit is to be installed on a roof curb or special

frame other than a YORK roof curb, gasketing

must be applied to all surfaces that come in contact

with the unit underside.

5. Maintain level tolerance to 1/2" maximum across the entire

length or width of the unit.

6. Elevate the unit sufficiently to prevent any blockage of the

air entrances by snow in areas where there will be snow ac-

cumulation. Check the local weather bureau for the ex-

pected snow accumulation in your area.

RIGGING AND HANDLING

Exercise care when moving the unit. Do not remove any

packaging until the unit is near the place of installation. Rig the

unit by attaching chain or cable slings to the lifting holes

provided in the base rails. Spreaders, whose length exceeds

the largest dimension across the unit, MUST be used across

the top of the unit.
BEFORE LIFTING A UNIT, MAKE SURE THAT ITS WEIGHT

IS DISTRIBUTED EQUALLY ON THE CABLES SO THAT IT

WILL LIFT EVENLY.
Units may also be moved or lifted with a forklift. Slotted

openings in the base rails are provided for this purpose.
LENGTH OF FORKS MUST BE A MINIMUM OF 42".
Remove the nesting brackets from the four corners on top of

the unit. All screws that are removed when taking these

brackets off must be replaced on the unit.

Refer to Table 2 for unit weights and to Figure 1 for approximate

center of gravity.

CLEARANCES

All units require certain clearances for proper operation and

service. Refer to Figure 5 for the clearances required for

combustible construction, servicing, and proper unit operation.

WARNING:Do not permit overhanging structures or shrubs to

obstruct outdoor air discharge outlet.

DUCTWORK

Ductwork should be designed and sized according to the

methods in Manual Q of the Air Conditioning Contractors of

America (ACCA).
A closed return duct system shall be used. This shall not

preclude use of economizers or outdoor fresh air intake. The

supply and return air duct connections at the unit should be

made with flexible joints to minimize the transmission of noise.
The supply and return air duct systems should be designed for

the CFM and static requirements of the job. They should NOT

be sized to match the dimensions of the duct connections on

the unit.

CAUTION: When fastening ductwork to the side duct flanges

on the unit, insert the screws through the duct

flanges only. DO NOT insert the screws through

the casing.

Outdoor ductwork must be insulated and water-

proofed.

Refer to Figure 5 for information concerning side and bottom

supply and return air duct openings.

FILTERS

1" filters are supplied with each unit. 2" replacement filters may

be used with no modification to the filter racks. Filters must

always be installed ahead of the evaporator coil and must be

035-12046-003-A-0204

Unitary Products Group

3

INSTALLATION

Voltage Variation

Min. / Max

.1

208/230V

187 / 253

460V

414 / 504

575V

518 / 630

Wet Bulb Temperature (°F) of Air on

Evaporator Coil, Min. / Max.

57 / 72

Dry Bulb Temperature (°F) of Air on

Condenser Coil, Min.

2

/ Max.

45 / 120

1

Utilization range “A” in accordance with ARI Standard 110.

2

A low ambient accessory is available for operation down to 0°F

TABLE 1 - UNIT APPLICATION DATA

APPROXIMATE
CENTER OF
GRAVITY

FRONT

67-3/4

30

30-1/2

15-1/8

FIG. 1 - CENTER OF GRAVITY

&

"

B

""

%

&

A

Dim.

3-5 Ton

A

19-3/4"

B

40-3/4"

This manual is related to the following products: