beautypg.com

York AY012MA321 User Manual

Page 11

background image

246814-YTG-D-0606

Unitary Products Group

11

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

AY012MA321

INDOOR COIL MODEL NO.

G2FD024S17

CONDENSER

ENTERING AIR

TEMPERATURE

ID CFM

250

400

550

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

65

T.C.

10.5

14.0

13.4

15.1

16.6

13.9

15.6

15.3

17.4

18.9

17.3

17.2

17.2

19.6

21.1

S.C.

10.7

9.7

8.1

8.3

7.0

14.2

12.2

10.5

11.1

8.6

17.6

14.6

12.9

13.9

10.3

KW

1.0

1.1

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

75

T.C.

10.4

13.6

13.1

14.8

16.5

13.6

15.2

14.9

16.7

18.4

16.8

16.8

16.7

18.7

20.4

S.C.

10.6

9.5

7.9

8.1

7.0

13.8

12.2

10.3

10.7

8.6

17.0

14.8

12.8

13.3

10.2

KW

1.1

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

85

T.C.

10.3

13.2

12.8

14.5

16.4

13.3

14.8

14.5

16.1

18.0

16.3

16.4

16.1

17.8

19.7

S.C.

10.3

9.2

7.6

7.9

6.9

13.4

12.1

10.2

10.3

8.6

16.5

15.0

12.7

12.7

10.2

KW

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

95

T.C.

10.2

12.7

12.4

14.1

16.3

13.0

14.3

14.0

15.5

17.6

15.8

16.0

15.6

16.9

18.9

S.C.

10.0

8.9

7.4

7.7

6.9

13.0

12.1

10.0

9.9

8.5

15.9

15.3

12.6

12.1

10.1

KW

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

105

T.C.

9.9

11.9

11.6

13.4

15.4

12.5

13.5

13.1

14.7

16.6

15.1

15.2

14.7

16.0

17.8

S.C.

9.8

8.5

7.0

7.5

6.5

12.5

11.4

9.5

9.7

8.0

15.3

14.3

12.1

11.9

9.6

KW

1.5

1.5

1.5

1.5

1.6

1.5

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

115

T.C.

9.6

11.1

10.7

12.7

14.6

12.0

12.7

12.3

13.9

15.7

14.4

14.4

13.8

15.1

16.8

S.C.

9.5

8.1

6.5

7.3

6.1

12.1

10.8

9.0

9.5

7.5

14.6

13.4

11.5

11.7

9.0

KW

1.6

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.8

1.7

1.7

1.8

1.8

125

T.C.

9.3

10.3

9.8

11.9

13.7

11.5

12.0

11.4

13.1

14.7

13.7

13.6

12.9

14.3

15.7

S.C.

9.2

7.8

6.1

7.0

5.7

11.6

10.1

8.6

9.3

7.1

14.0

12.5

11.0

11.5

8.4

KW

1.8

1.8

1.8

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Air Handler

Coil

T.C.

S.C.

KW

AHP18

1.00

1.00

1.00

FC/MC/PC18

1.00

1.00

1.00

G4FA030S14T2A

1.00

1.00

1.00

G4FA036S17T2A

1.00

1.00

1.00

G4FA036S21T2A

1.00

1.00

1.00

G4FD024H14T2A

1.00

1.00

1.00

G4FD024H17T2A

1.00

1.00

1.00

G4FD030H17T2A

1.00

1.00

1.00

G4FD035H14T2A

1.00

1.00

1.00

HC24

1.00

1.00

1.00

UC18

1.00

1.00

1.00

Variable Speed

Furnace

Coil

T.C.

S.C.

KW