Installation Instructions
975-0301-01-01
7
AC/DC Distribution Panel
The XADC may be pre-installed with an AC/DC Distribution Panel. The panel is
available in two configurations which provides the approved wiring boxes for AC
and DC connections:
30A (Part Number: 810-0030-00 XADC P30) – eight output breakers
50A (Part Number: 810-0050-00 XADC P50) – 10 output breakers
In each configuration there are also 11 unassigned DC fuses and four reserved
fuses for the battery connections.
Figure 3 and Figure 5 show the main components of the XADC with AC/DC
Distribution Panel.
Figure 2 XADC Internal Components
Item
Description
1
AC wiring compartment hole
2
Black AC line cable
3
White AC neutral cable
4
Green AC ground cable
5
Grommet (supplied)
6
Strain relief (not supplied)
7
DC wiring compartment hole ½ in. - 3/8 in. trade size (with ¾ in. knockout)
8
DC fuses
9
DC positive (+) and negative (-) connection lugs
POS
(+)
NEG
(-)
1
2
3
4
7
9
8
6
5
Important:
The XADC P30 and XADC P50 panels are not intended for use with rigid