English - troubleshooting, Troubleshooting product registration, Product registration card – Wagner PaintMate Plus User Manual
Page 11
11
Problem
There is paint leakage on the roller arm
assembly.
Plunger is difficult to pull/push.
The fill tube will not fill with paint or
paint leaks from fill valve.
Solution
1. Turn the seal around.
2. Clean and properly lubricate.
3. Clean and properly lubricate.
4. Clean connecting areas.
5. Replace the O-rings*.
6. Replace the roller cover*.
7. Replace the core or cap*.
8. Call customer service.
1. Lubricate the O-rings on the plunger.
a) Insert fill tube firmly into fill valve and
twist fill tube several times to break up
paint residue.
b) If the problem persists, refer to the steps
below to clean the fill valve components.
Cause
1. The seal on the arm is backwards.
2. The seal and cap were not properly cleaned.
3. The O-ring and the connecting area were not
cleaned properly.
4. Paint residue on connecting areas.
5. The O-rings are damaged or missing.
6. The roller cover is worn or damaged.
7. The core or cap is worn or damaged.
8. The bearing areas are worn.
1. Plunger O-rings are not lubricated.
1. Paint residue on fill valve components.
English - Troubleshooting
*Replacement parts available by calling customer service
Retaining disk
Locking cap
Duckbill valve
Valve housing
Connecting
area
1. Unscrew the locking cap on the valve housing by turning it
counterclockwise.
2. Remove the retaining disk and the duckbill from the valve housing.
3. Clean these parts thoroughly using the appropriate cleaning solution.
4. Replace the duckbill valve and retainer disk.
5. Screw the locking cap on the valve housing by turning it
clockwise
Have you tried the recommendations above and are still having problems? In the United States, to speak to a customer
service representative, call our Customer Service at 1-800-760-3844 Monday through Friday between 8:00 AM and 4:30
PM Central time. An automated Self-Help option is also available at 1-800-760-3844, seven days a week, twenty-four
hours a day.
Product Registration Card
Send in your product registration card or register online at www.wagnerspraytech.com. Proper registration will serve as proof of purchase
in the event your original receipt becomes misplaced or lost. Returning this card will expedite the processing of your warranty. Be sure
you write your unit’s
date code on the card before sending it. The date code is located on the Power Trigger
®
of your unit (for example,
T087A). The additional information will also help us to develop new products that best meet your needs and desires.