beautypg.com

Windsor Saber Compact 22 User Manual

Page 19

background image

English

19

Errors with display

Overload
display

Display

Error

Remedy

Perma-
nent light

Pcb. Störung=4
Pcb. fault=4

Defective electronics

Call customer service.

blinks
once

Bürstm.Störung=1
Brushmot.fault=1

Short circuit in the
brush motor

Call customer service.

Saugtb.Störung=1
Vac.mot. fault=1

Short circuit in vacu-
um motor

Ventil.Störung=1
Valve fault=1

Short circuit in soleno-
id valve

Fahrmt.Störung=1
Drivemot.fault=1

Short circuit in drive
motor

blinks
twice

Bürstm.Störung=2
Brushmot.fault=2

Cable rupture in the
brush motor

Call customer service.

Saugtb.Störung=2
Vac.mot. fault=2

Cable rupture in vacu-
um motor

Ventli.Störung=2
Valve fault=2

Cable rupture in sole-
noid valve

Fahrmt.Störung=2
Drivemot.fault=2

Cable rupture in drive
motor

blinks th-
rice

Heiss, abkühlen!
Hot, let cool!

Temperature in the
electronics system is
high.

Let the electronics system cool
down for at least 15 minutes.

Saugtb.Störung=3
Vac.mot. fault=3

Overload vacuum mo-
tor

Turn the program selection
switch to OFF or Drive. Then
select again the cleaning pro-
gram. If the fault recurs, call
customer service.

Bürstenüberlast!
Brush Overload!

Overload on brush
motor

Fahrmt.Störung=3
Drivemot.fault=3

Overload drive motor

blinks four
times

Prüfe Battspanng
Check Battery!

Battery voltage is not
between 17 and 33 V

Call customer service.

Battery voltage is too
high while charging

Stop charging. You can still use
the machine; however, call Cu-
stomer Service

Batteriefehler!
Battery fault!

Battery fault

Notaus-Schalter!
Emergency button

Emergency-stop but-
ton has been pressed
while charging the bat-
tery.

Release emergency-stop but-
ton. .

This manual is related to the following products: